H1
Zanussi
High Temperature Alarm Condition
Display shows H1 or 'HI', audible alarm sounds; cabinet temperature is too high.
Advertisements
Possible Causes
Door left open or not sealing, Warm bottles loaded all at once, Blocked air circulation inside cabinet, Failing compressor or refrigerant leak
How to Fix / Troubleshooting
Safety: No internal electrical work is required for basic checks. Unplug the unit if you need to remove panels.
Steps:
- Check door closure: Ensure the door is fully closed and the gasket is clean and undamaged. Remove any bottles preventing full closure.
- Allow stabilization: If you recently loaded many warm bottles, the temperature will rise temporarily. Close the door and allow 12–24 hours for the temperature to recover.
- Improve airflow: Space bottles so that air can circulate around them. Avoid blocking the internal fan vents.
- Check ambient temperature: Ensure the wine cooler is not installed in a very hot location (e.g., next to an oven or in direct sunlight), as this can trigger high temperature alarms.
- Clean condenser and check fan: If the alarm persists, clean the condenser coil and verify the condenser fan is running when the compressor is on.
When to call a technician: If the compressor runs continuously, the condenser is clean, and the unit still cannot cool, a sealed system fault is likely and requires professional service.
Advertisements
Repair Difficulty
Easy
2/5