Zanussi
Intermittent Temperature Control / Sensor Drift
Wine cooler is too warm intermittently; temperature fluctuates widely without any error code.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Aging cabinet NTC sensor with drift, Loose sensor connection on PCB, Poor door seal causing warm air ingress, Control board relay intermittently failing
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing sensors or the control board.
Steps:
- Verify with a thermometer: Place an accurate thermometer inside the cabinet to confirm actual temperature versus display.
- Inspect door gasket: Check for gaps, tears, or hardened sections. Close the door on a sheet of paper at several points; if it pulls out easily, the seal is weak.
- Check sensor mounting: Ensure the cabinet NTC sensor is firmly attached to the interior wall and not hanging loose, which can cause erratic readings.
- Reseat connectors: Remove the rear panel and reseat the sensor connector on the main PCB.
- Replace suspect sensor: If fluctuations persist, replace the cabinet NTC sensor with a Zanussi-compatible part.
Note: If replacing the sensor does not stabilize temperature, the main control board may have an intermittent fault and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.