Zanussi Normal Refrigerant Flow Noise

Wine cooler produces a gurgling or hissing sound periodically.

Advertisements

Possible Causes

Refrigerant flowing through capillary tube and evaporator, Expansion and contraction of tubing, Defrost water dripping on hot components

How to Fix / Troubleshooting

Safety: No repair is usually required. Do not attempt to puncture or modify any sealed system components.

Steps:

  • Identify noise pattern: Gurgling or hissing that occurs when the compressor starts or stops is typically normal.
  • Check for leaks: Ensure there is no oily residue on tubing or around joints, which could indicate a refrigerant leak.
  • Verify performance: If the cooler maintains correct temperature and there are no error codes, the noise is likely normal operation.

Action: No parts need replacing unless accompanied by poor cooling or visible leaks, in which case contact a refrigeration technician.