F7
Fujitsu
Inverter Compressor Speed Control Error
Indoor unit shows F7, abnormal compressor speed control, unit may not reach set temperature
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty inverter power module, Incorrect DC bus voltage, Compressor internal fault, Loose compressor connector
How to Fix / Troubleshooting
Safety first: Inverter circuits carry lethal voltages even after power is removed. Only qualified technicians should open the outdoor control box and test inverter components.
- Homeowner checks:
- Ensure outdoor unit has stable power supply (no frequent brownouts).
- Verify outdoor coil and fan are clean and unobstructed.
- Technician diagnostics:
- Check DC bus voltage and AC input.
- Measure compressor winding resistance and insulation.
- Inspect inverter module for burn marks or cracked solder joints.
- Likely repair: Replace the outdoor inverter PCB assembly if compressor tests good but F7 persists. If compressor is faulty, compressor and possibly outdoor unit replacement is required.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Inverter PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements