E0
Indoor unit will not operate, display shows E0 shortly after power-on
Indoor Unit EEPROM Communication Error
E1
Outdoor unit does not start, indoor unit shows E1 or flashes timer LED in E1 pattern
Indoor-Outdoor Communication Failure
E2
Indoor unit stops shortly after starting, E2 displayed or timer LED flashes E2 pattern
Indoor Room Temperature Sensor (Thermistor) Fault
E3
Unit stops cooling or heating, E3 error indicated, fan may continue running
Indoor Heat Exchanger (Coil) Temperature Sensor Fault
E4
Outdoor unit does not start compressor, E4 error displayed on indoor unit
Outdoor Unit EEPROM or Control Fault
E5
Indoor unit stops, E5 error, often during heating mode changeover
Outdoor Discharge Pipe Temperature Sensor Fault
E6
Unit stops with E6 error, often during heating defrost or low ambient operation
Outdoor Heat Exchanger (Coil) Temperature Sensor Fault
E7
Indoor unit shows E7, outdoor fan may not run or runs erratically
Outdoor Fan Motor or Fan Feedback Error
E8
Indoor unit stops, E8 displayed, often associated with abnormal compressor operation
Compressor Overload or Inverter Module Protection
E9
Indoor unit shows E9, unit may stop shortly after starting
Indoor Fan Motor or Fan Feedback Error
F0
Indoor unit displays F0, unit may not start or may shut down quickly
Refrigerant System Low Pressure / Undercharge Protection
F1
Indoor unit shows F1, unit may stop during heavy load conditions
High Pressure Protection / Overcharge or Airflow Fault
F2
Indoor unit displays F2, unit may stop in heating mode
Defrost Sensor or Defrost Control Error
F3
Indoor unit shows F3, unit may shut down during extreme temperatures
Discharge Temperature High Protection
F4
Indoor unit displays F4, unit may not heat properly
Outdoor Ambient Temperature Sensor Fault
F5
Indoor unit shows F5, unit may not respond correctly to remote control temperature settings
Indoor Intake Air Temperature Sensor Fault
F6
Indoor unit displays F6, unit may not control coil temperature correctly
Indoor Heat Exchanger Outlet Temperature Sensor Fault
F7
Indoor unit shows F7, abnormal compressor speed control, unit may not reach set temperature
Inverter Compressor Speed Control Error
F8
Indoor unit shows F8, unit may stop during heating or cooling under heavy load
Current Sensor / Overcurrent Detection Error
F9
Indoor unit displays F9, unit may not operate in certain modes
Four-Way Valve (Reversing Valve) Control Error
H0
Indoor unit shows H0, unit may not respond to remote control
Indoor Unit Remote Receiver or PCB Error
H1
Indoor unit shows H1, unit may not start compressor
Indoor-Outdoor Addressing or Capacity Mismatch Error
H2
Indoor unit shows H2, unit may run at reduced capacity
Indoor Fan Speed Feedback Error (Abnormal RPM)
H3
Indoor unit shows H3, compressor does not start
Compressor Lock or Start Failure Protection
H4
Indoor unit shows H4, unit may stop unexpectedly
Indoor PCB Overheat or Power Supply Error
H5
Indoor unit shows H5, unit may not operate in certain modes or capacities
Outdoor Unit Capacity Control or Expansion Valve Error
H6
Indoor unit shows H6, outdoor fan may not operate correctly
Outdoor Fan Speed Feedback Error
H7
Indoor unit shows H7, unit may not operate multiple indoor units correctly (multi-split)
Indoor Unit Capacity or Port Assignment Error (Multi-Split)
H8
Indoor unit shows H8, unit may run but with abnormal performance
Indoor Coil Frost Protection or Low Airflow Error
H9
Indoor unit shows H9, unit may not respond to wired controller correctly
Wired Remote Controller Communication Error
Symptom
Burning or electrical smell from indoor or outdoor unit
Overheating Electrical Component or Wiring Fault
Symptom
Indoor fan runs but compressor and outdoor fan do not start; only room air is circulated
Outdoor Unit Not Running
Symptom
Indoor unit displays lights but does not respond to any commands (frozen controls)
Control Lockup / Microcontroller Hang
Symptom
Indoor unit emits a musty or moldy odor when starting
Biological Growth on Indoor Coil or Drain Pan
Symptom
Indoor unit louvers do not move or are stuck in one position
Louver Motor or Linkage Failure
Symptom
Indoor unit runs but does not cool effectively; air is only slightly cool or room never reaches set temperature
Insufficient Cooling Capacity / Performance Degradation
Symptom
Indoor unit runs but does not heat effectively in heating mode; air is lukewarm and room stays cold
Insufficient Heating Capacity / Defrost or Refrigerant Issue
Symptom
Loud buzzing, humming, or rattling noise from the outdoor unit
Outdoor Mechanical or Electrical Noise
Symptom
Loud rattling or vibrating noise from the indoor unit during operation
Indoor Mechanical Vibration / Loose Components
Symptom
Remote control does not operate the indoor unit, but unit works from manual button (if present)
Remote Control Signal Reception Failure
Symptom
Unit blows cold air in heating mode or hot air in cooling mode intermittently
Reversing Valve or Mode Control Malfunction
Symptom
Unit frequently starts and stops (short cycling) without reaching set temperature
Short Cycling / Control or Capacity Issue
Symptom
Unit will not start at all; no lights or response from indoor unit
No Power to Indoor Unit
Symptom
Water dripping from the outdoor unit or piping during cooling operation
Normal Condensation or Insulation Failure
Symptom
Water leaking from the indoor unit onto the wall or floor during cooling
Indoor Condensate Drainage Failure