H5
Fujitsu
Outdoor Unit Capacity Control or Expansion Valve Error
Indoor unit shows H5, unit may not operate in certain modes or capacities
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck electronic expansion valve (EEV), Faulty EEV coil or stepper motor, Wiring fault between PCB and EEV, Outdoor PCB control error
How to Fix / Troubleshooting
Safety first: Turn off power at the outdoor disconnect. The expansion valve is part of the sealed refrigerant circuit; do not attempt to open it.
- Listen for EEV operation: When the system starts, a technician may listen closely for clicking or buzzing from the EEV, indicating movement.
- Check wiring: Inspect the EEV coil wiring harness and connector for damage or loose connections.
- Technician tasks:
- Test EEV coil resistance and stepper function.
- Check for proper valve operation via service mode.
- Replace the EEV assembly or outdoor PCB if confirmed faulty.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Electronic Expansion Valve (EEV)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements