Possible Causes

Undersized supply or return ducts, Closed or undersized return grille, High blower speed setting on Goodman air handler, Filter with too high resistance

How to Fix / Troubleshooting

Safety first: Turn off power before adjusting blower speed taps or ECM settings.

Steps to reduce noise:

  • 1. Open all vents: Ensure all supply and return registers are fully open to reduce static pressure.
  • 2. Use appropriate filters: Replace very restrictive filters with medium-MERV filters recommended by Goodman for your system.
  • 3. Check for blocked returns: Make sure furniture or doors are not blocking return grilles.
  • 4. Blower speed adjustment: On some Goodman units, blower speed can be reduced by moving a speed tap or changing ECM settings. This should be done by a technician to avoid coil icing or reduced capacity.

When to call a professional: Persistent noise may indicate duct redesign is needed; an HVAC contractor can measure static pressure and recommend changes.