Goodman

Goodman Air Conditioners Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
d0
Goodman communicating thermostat or control shows d0 and system does not respond to commands
Communication Loss with Outdoor Unit
d1
Goodman communicating thermostat shows d1 and cooling capacity is limited
Low Suction Pressure / Low Load Condition Detected
d2
Goodman communicating thermostat shows d2 and system may shut down on high pressure
High Discharge or Head Pressure Detected
d3
Goodman communicating thermostat shows d3 and compressor operation is restricted
Compressor Protection / Locked Rotor or Overcurrent Event Logged
d4
Goodman communicating thermostat shows d4 and system may not reach setpoint
Capacity Limit / Long Run Time Protection
E0
Goodman air conditioner thermostat or wall control displays E0 and system will not run
Communication Fault Between Indoor Control Board and Thermostat
E1
Goodman ductless mini-split or packaged AC displays E1 and stops cooling
Indoor/Outdoor Unit Communication Failure
E2
Goodman mini-split indoor unit shows E2 and cooling stops intermittently
Indoor Coil (Evaporator) Temperature Sensor Fault
E3
Goodman mini-split or inverter condenser shows E3 and outdoor fan or compressor will not run
Outdoor Fan Motor or Fan Feedback Fault
E4
Goodman mini-split shows E4 and shuts down during operation
High Discharge Temperature / Compressor Overheat Protection
E5
Goodman mini-split or inverter condenser displays E5 and compressor does not start or trips quickly
Compressor Overcurrent / Overload Protection Trip
E6
Goodman mini-split indoor unit shows E6 and system will not run
Indoor Fan Motor Fault
E7
Goodman mini-split shows E7 and unit stops shortly after starting
Mode Conflict or 4-Way Reversing Valve Fault
E8
Goodman mini-split indoor unit shows E8 and airflow is reduced or unit shuts down
Indoor Coil Freeze Protection / Low Evaporator Temperature
E9
Goodman mini-split displays E9 and unit will not operate
EEPROM / Memory Error on Control Board
F0
Goodman inverter condenser or mini-split shows F0 and does not start cooling
Refrigerant System Low Charge / Undercharge Protection
F1
Goodman inverter system displays F1 and shuts down
Indoor Ambient Temperature Sensor Fault
F2
Goodman inverter or mini-split shows F2 and cooling/heating is disabled
Outdoor Ambient Temperature Sensor Fault
F3
Goodman inverter condenser shows F3 and unit cycles off on high pressure
High Pressure Protection / Condenser Overpressure
F4
Goodman inverter system shows F4 and compressor does not run
Compressor Discharge Temperature Sensor Fault
F5
Goodman inverter or mini-split shows F5 and unit stops during operation
Evaporator Coil Temperature Sensor Fault (Indoor)
F6
Goodman inverter system displays F6 and compressor speed is limited or unit shuts down
Current Sensor / Inverter Module Fault
F7
Goodman inverter or mini-split shows F7 and outdoor fan or compressor operation is abnormal
Phase Loss / Phase Protection (Three-Phase Units)
F8
Goodman inverter system shows F8 and unit derates or shuts down in high ambient conditions
Outdoor Coil Temperature Sensor Fault
F9
Goodman inverter or mini-split displays F9 and system will not operate normally
Indoor-Outdoor Capacity Mismatch or Configuration Error
Symptom
Goodman air conditioner causes breaker to trip when it starts
High Inrush Current / Electrical Short
Symptom
Goodman air conditioner emits a musty or moldy smell when running
Biological Growth on Evaporator Coil or in Drain Pan
Symptom
Goodman air conditioner freezes up with ice on the indoor coil or refrigerant lines
Evaporator Coil Icing
Symptom
Goodman air conditioner indoor coil or refrigerant lines sweat excessively and drip water
Condensation on Uninsulated or Cold Surfaces
Symptom
Goodman air conditioner indoor unit is very noisy with air rushing or whistling sounds
Excessive Air Velocity / Duct Restriction
Symptom
Goodman air conditioner leaks water inside the house around the air handler or furnace
Condensate Drainage Failure
Symptom
Goodman air conditioner makes a high-pitched squealing or screeching noise from the indoor unit
Indoor Blower or Motor Bearing Failure
Symptom
Goodman air conditioner outdoor unit fan does not run but compressor is running and very hot
Condenser Fan Failure
Symptom
Goodman air conditioner outdoor unit is very loud or rattling during operation
Excessive Vibration / Mechanical Noise
Symptom
Goodman air conditioner outdoor unit will not turn off even when thermostat is satisfied
Stuck Contactor or Control Relay
Symptom
Goodman air conditioner produces warm air from vents instead of cool air
Loss of Cooling / Reversing Valve or Refrigerant Issue
Symptom
Goodman air conditioner runs but does not cool the house adequately
Insufficient Cooling Capacity / Poor Heat Transfer
Symptom
Goodman air conditioner runs continuously and rarely shuts off
Continuous Operation / Inability to Reach Setpoint
Symptom
Goodman air conditioner short cycles (turns on and off frequently)
Short Cycling / Improper Control or Capacity
Symptom
Goodman air conditioner thermostat shows power but does not call for cooling
Thermostat Configuration or Wiring Issue
Symptom
Goodman air conditioner will not start at all (no fan, no compressor)
No Power / Control Circuit Failure
Symptom
Goodman outdoor condenser fan runs but compressor does not start
Compressor Start Failure
Symptom
Goodman outdoor unit runs (fan and compressor) but indoor blower does not run
Indoor Blower Motor or Control Failure