E5
Gorenje Compressor Overcurrent or Overload Protection Trip

Indoor unit shows E5; compressor may not start or stops quickly; sometimes accompanied by humming from outdoor unit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted or partially shorted compressor windings, Blocked or seized outdoor fan causing high current, Low supply voltage or wiring issue, Faulty outdoor inverter/drive PCB

How to Fix / Troubleshooting

Safety: This fault involves high current and compressor protection. Turn off power at the main breaker. Do not bypass any safety devices.

Basic checks (user-level):

  • Ventilation: Ensure the outdoor Gorenje unit has at least the recommended clearance on all sides and is not blocked by debris, plants, or covers.
  • Outdoor fan: With power off, spin the outdoor fan blade by hand. It should rotate freely without scraping. Remove any obstructions.
  • Power supply: Confirm the breaker is correctly rated and not tripping repeatedly. If lights dim when the unit starts, have an electrician check supply voltage and wiring.

Advanced checks (technician recommended):

  • Measure compressor winding resistance and insulation.
  • Check outdoor PCB for burnt components or loose terminals.
  • Verify running current against Gorenje nameplate data.

If E5 recurs after ensuring airflow and supply are correct, contact a qualified HVAC technician; compressor or inverter PCB replacement may be required.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter PCB or Compressor
Check Price on Amazon

We may earn a commission from links on this page.