Gorenje Air Conditioners Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
C0
C0 displayed; unit may not respond correctly to remote commands.
Indoor EEPROM or Configuration Error
E1
Indoor unit displays E1 and stops cooling or heating; fan may still run briefly then shut down.
Indoor Room Temperature Sensor (NTC) Fault
E2
Indoor unit shows E2 and stops cooling; unit may start then shut down quickly.
Indoor Evaporator Coil Temperature Sensor Fault
E3
Outdoor unit does not start or stops shortly after starting; indoor unit displays E3.
Outdoor Coil Temperature Sensor Fault
E4
Unit stops during heating mode; indoor unit may blow cold air briefly then shut down with E4 displayed.
Defrost or Outdoor Discharge Temperature Sensor Fault
E5
Indoor unit shows E5; compressor may not start or stops quickly; sometimes accompanied by humming from outdoor unit.
Compressor Overcurrent or Overload Protection Trip
E6
Indoor unit displays E6; system does not start or stops; sometimes indoor fan runs but no cooling or heating.
Communication Failure Between Indoor and Outdoor Units
E7
Indoor unit shows E7; louver may not move or may be stuck in one position; airflow direction cannot be adjusted.
Indoor Louver Stepper Motor or Position Feedback Fault
E8
Indoor unit displays E8; unit may stop unexpectedly, especially in high load conditions.
Indoor Fan Motor or Fan Speed Feedback Fault
E9
Indoor unit shows E9; sometimes associated with water leakage or abnormal defrost behavior.
Indoor Condensate Level Sensor or Float Switch Fault
F0
Unit displays F0 and does not cool or heat; may start briefly then shut down.
Refrigerant System Low Charge or Leakage Protection
F1
Display shows F1; unit may run but with poor performance or may shut down intermittently.
Indoor Ambient Temperature Sensor Out of Range
F2
F2 error; unit may stop during cooling or show erratic coil temperature behavior (icing or short cycling).
Evaporator Coil Sensor Out of Range or Frost Protection Fault
F3
F3 displayed; unit may stop in heating mode or show poor heating performance.
Outdoor Ambient Temperature Sensor Fault
F4
F4 error; compressor may not start or may shut down quickly; often in heating mode.
Outdoor Discharge Pipe Sensor Out of Range
F5
F5 displayed; unit may stop in cooling mode, especially in high ambient temperatures.
Condenser High Temperature or Overload Protection
H1
H1 displayed during heating; indoor unit may blow cold air or stop airflow for a period.
Defrost Mode Indication / Defrost Protection
H3
H3 error; unit stops and will not restart until power is cycled; often occurs under heavy load.
Compressor Overheat Protection
H5
H5 displayed; unit may not start or may shut down shortly after starting.
IPM (Inverter Power Module) Protection
P0
P0 displayed; unit may not start compressor or may run at reduced capacity.
Inverter Module or DC Bus Voltage Protection
P1
P1 error; unit may stop and display a water-related or protection message (on some floor/portable Gorenje ACs).
High Condensate Level or Drain Pump Protection
P2
P2 displayed; unit may limit operation or stop, especially in heating mode.
Outdoor Ambient Low Temperature or Anti-freeze Protection
P4
P4 error; unit may stop or run at reduced capacity.
Inverter Module Temperature Protection
Symptom
Air conditioner does not start at all; no lights on indoor unit, no response to remote.
No Power to Indoor Unit
Symptom
Air conditioner runs but does not cool the room effectively; supply air feels only slightly cooler than room air.
Insufficient Cooling Capacity / Performance Loss
Symptom
Ice forms on the indoor unit evaporator coil or on the front panel during cooling.
Evaporator Icing / Low Airflow or Refrigerant Issue
Symptom
Indoor unit blows air but there is a noticeable chemical or burning smell.
Electrical Overheating or Contaminant on Heater/Coil
Symptom
Indoor unit display or LEDs do not work, but the unit still responds to remote and operates.
Display Panel or LED Board Failure
Symptom
Indoor unit emits a musty or moldy smell when starting.
Biological Growth on Evaporator Coil and Drain Pan
Symptom
Indoor unit produces a high-pitched whistling or hissing noise during operation.
Airflow Restriction or Refrigerant Flow Noise
Symptom
Indoor unit receives power (lights on) but will not start cooling or heating when commanded.
Control or Mode Selection Fault
Symptom
Indoor unit vibrates excessively and causes noise or wall resonance.
Improper Mounting or Imbalanced Blower
Symptom
Loud humming, grinding, or squealing noise from the outdoor unit.
Outdoor Fan or Compressor Mechanical Fault
Symptom
Loud rattling or buzzing noise from the indoor unit during operation.
Indoor Mechanical Vibration or Loose Components
Symptom
Outdoor unit coil becomes heavily iced over in heating mode and heating performance drops.
Outdoor Coil Frosting / Defrost Malfunction
Symptom
Outdoor unit does not start (no fan, no compressor) while indoor unit appears to run normally.
Outdoor Unit Power or Control Failure
Symptom
Outdoor unit runs but indoor fan does not blow air, or airflow is extremely weak.
Indoor Fan Motor or Blower Obstruction
Symptom
Remote control does not operate the indoor unit; no beep or response.
Remote Control or IR Receiver Failure
Symptom
Unit frequently turns on and off (short cycling) without maintaining stable room temperature.
Short Cycling / Control Instability
Symptom
Unit trips the circuit breaker immediately or shortly after starting.
Electrical Short or Overcurrent
Symptom
Water dripping from the front of the indoor unit or down the wall during cooling.
Indoor Unit Water Leakage
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| C0 |
C0 displayed; unit may not respond correctly to remote commands.
|
Indoor EEPROM or Configuration Error | View Details |
| E1 |
Indoor unit displays E1 and stops cooling or heating; fan may still run briefly then shut down.
|
Indoor Room Temperature Sensor (NTC) Fault | View Details |
| E2 |
Indoor unit shows E2 and stops cooling; unit may start then shut down quickly.
|
Indoor Evaporator Coil Temperature Sensor Fault | View Details |
| E3 |
Outdoor unit does not start or stops shortly after starting; indoor unit displays E3.
|
Outdoor Coil Temperature Sensor Fault | View Details |
| E4 |
Unit stops during heating mode; indoor unit may blow cold air briefly then shut down with E4 displayed.
|
Defrost or Outdoor Discharge Temperature Sensor Fault | View Details |
| E5 |
Indoor unit shows E5; compressor may not start or stops quickly; sometimes accompanied by humming from outdoor unit.
|
Compressor Overcurrent or Overload Protection Trip | View Details |
| E6 |
Indoor unit displays E6; system does not start or stops; sometimes indoor fan runs but no cooling or heating.
|
Communication Failure Between Indoor and Outdoor Units | View Details |
| E7 |
Indoor unit shows E7; louver may not move or may be stuck in one position; airflow direction cannot be adjusted.
|
Indoor Louver Stepper Motor or Position Feedback Fault | View Details |
| E8 |
Indoor unit displays E8; unit may stop unexpectedly, especially in high load conditions.
|
Indoor Fan Motor or Fan Speed Feedback Fault | View Details |
| E9 |
Indoor unit shows E9; sometimes associated with water leakage or abnormal defrost behavior.
|
Indoor Condensate Level Sensor or Float Switch Fault | View Details |
| F0 |
Unit displays F0 and does not cool or heat; may start briefly then shut down.
|
Refrigerant System Low Charge or Leakage Protection | View Details |
| F1 |
Display shows F1; unit may run but with poor performance or may shut down intermittently.
|
Indoor Ambient Temperature Sensor Out of Range | View Details |
| F2 |
F2 error; unit may stop during cooling or show erratic coil temperature behavior (icing or short cycling).
|
Evaporator Coil Sensor Out of Range or Frost Protection Fault | View Details |
| F3 |
F3 displayed; unit may stop in heating mode or show poor heating performance.
|
Outdoor Ambient Temperature Sensor Fault | View Details |
| F4 |
F4 error; compressor may not start or may shut down quickly; often in heating mode.
|
Outdoor Discharge Pipe Sensor Out of Range | View Details |
| F5 |
F5 displayed; unit may stop in cooling mode, especially in high ambient temperatures.
|
Condenser High Temperature or Overload Protection | View Details |
| H1 |
H1 displayed during heating; indoor unit may blow cold air or stop airflow for a period.
|
Defrost Mode Indication / Defrost Protection | View Details |
| H3 |
H3 error; unit stops and will not restart until power is cycled; often occurs under heavy load.
|
Compressor Overheat Protection | View Details |
| H5 |
H5 displayed; unit may not start or may shut down shortly after starting.
|
IPM (Inverter Power Module) Protection | View Details |
| P0 |
P0 displayed; unit may not start compressor or may run at reduced capacity.
|
Inverter Module or DC Bus Voltage Protection | View Details |
| P1 |
P1 error; unit may stop and display a water-related or protection message (on some floor/portable Gorenje ACs).
|
High Condensate Level or Drain Pump Protection | View Details |
| P2 |
P2 displayed; unit may limit operation or stop, especially in heating mode.
|
Outdoor Ambient Low Temperature or Anti-freeze Protection | View Details |
| P4 |
P4 error; unit may stop or run at reduced capacity.
|
Inverter Module Temperature Protection | View Details |
| – |
Air conditioner does not start at all; no lights on indoor unit, no response to remote.
|
No Power to Indoor Unit | View Details |
| – |
Air conditioner runs but does not cool the room effectively; supply air feels only slightly cooler than room air.
|
Insufficient Cooling Capacity / Performance Loss | View Details |
| – |
Ice forms on the indoor unit evaporator coil or on the front panel during cooling.
|
Evaporator Icing / Low Airflow or Refrigerant Issue | View Details |
| – |
Indoor unit blows air but there is a noticeable chemical or burning smell.
|
Electrical Overheating or Contaminant on Heater/Coil | View Details |
| – |
Indoor unit display or LEDs do not work, but the unit still responds to remote and operates.
|
Display Panel or LED Board Failure | View Details |
| – |
Indoor unit emits a musty or moldy smell when starting.
|
Biological Growth on Evaporator Coil and Drain Pan | View Details |
| – |
Indoor unit produces a high-pitched whistling or hissing noise during operation.
|
Airflow Restriction or Refrigerant Flow Noise | View Details |
| – |
Indoor unit receives power (lights on) but will not start cooling or heating when commanded.
|
Control or Mode Selection Fault | View Details |
| – |
Indoor unit vibrates excessively and causes noise or wall resonance.
|
Improper Mounting or Imbalanced Blower | View Details |
| – |
Loud humming, grinding, or squealing noise from the outdoor unit.
|
Outdoor Fan or Compressor Mechanical Fault | View Details |
| – |
Loud rattling or buzzing noise from the indoor unit during operation.
|
Indoor Mechanical Vibration or Loose Components | View Details |
| – |
Outdoor unit coil becomes heavily iced over in heating mode and heating performance drops.
|
Outdoor Coil Frosting / Defrost Malfunction | View Details |
| – |
Outdoor unit does not start (no fan, no compressor) while indoor unit appears to run normally.
|
Outdoor Unit Power or Control Failure | View Details |
| – |
Outdoor unit runs but indoor fan does not blow air, or airflow is extremely weak.
|
Indoor Fan Motor or Blower Obstruction | View Details |
| – |
Remote control does not operate the indoor unit; no beep or response.
|
Remote Control or IR Receiver Failure | View Details |
| – |
Unit frequently turns on and off (short cycling) without maintaining stable room temperature.
|
Short Cycling / Control Instability | View Details |
| – |
Unit trips the circuit breaker immediately or shortly after starting.
|
Electrical Short or Overcurrent | View Details |
| – |
Water dripping from the front of the indoor unit or down the wall during cooling.
|
Indoor Unit Water Leakage | View Details |