F4
Gorenje
Outdoor Discharge Pipe Sensor Out of Range
F4 error; compressor may not start or may shut down quickly; often in heating mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective discharge pipe sensor, Sensor not clamped properly to discharge line, Overheating due to blocked outdoor coil, Outdoor PCB misreading sensor
How to Fix / Troubleshooting
Safety: Turn off power and wait for components to cool before touching any pipes.
Steps:
- Clean outdoor coil: Remove debris and wash the condenser coil with low-pressure water, avoiding the control box.
- Check sensor clamp: Ensure the discharge sensor is tightly attached to the hot gas line and insulated as originally installed.
- Replace sensor: If F4 persists, replace the discharge pipe sensor.
- Technician check: If a new sensor does not help, the system may be overcharged or have a PCB fault; call a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Discharge Pipe Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.