Gorenje
Evaporator Icing / Low Airflow or Refrigerant Issue
Ice forms on the indoor unit evaporator coil or on the front panel during cooling.
Advertisements
Possible Causes
Very dirty air filters, Blocked return or supply air, Low indoor fan speed with low load, Low refrigerant charge, Faulty evaporator sensor or control
How to Fix / Troubleshooting
Safety: Do not chip ice with sharp objects; this can damage the coil.
Steps:
- Turn off cooling: Switch the unit to Fan mode only to melt the ice.
- Clean filters and coil: After ice melts, clean filters and inspect the coil for dirt.
- Check airflow: Ensure furniture or curtains are not blocking the indoor unit.
- Adjust settings: Avoid setting the temperature extremely low for long periods; use a moderate setpoint.
- Technician check: If icing recurs, have a technician check refrigerant charge and sensor operation.