Control or Mode Selection Fault
Indoor unit receives power (lights on) but will not start cooling or heating when commanded.
Advertisements
Possible Causes
Incorrect mode or temperature setting, Remote control not communicating properly, Child lock or timer function active, Faulty indoor PCB relay or triac
How to Fix / Troubleshooting
Steps:
- Verify mode: Set the Gorenje remote to Cool or Heat (not Fan or Dry) and set temperature well below (cooling) or above (heating) room temperature.
- Cancel timers: Check for any timer icons on the display. Cancel all timers and schedules.
- Remote batteries: Replace batteries and ensure there is a clear line of sight to the indoor unit IR receiver.
- Manual start: Some models have an emergency operation button under the front panel. Press it to test basic operation.
- Power reset: Turn off power at the breaker for 5–10 minutes, then restore.
- If still no start: The indoor PCB or communication with the outdoor unit may be faulty and should be checked by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Remote Control or Indoor Main PCB
Check Price on Amazon
We may earn a commission from links on this page.