F2
Gorenje Evaporator Coil Sensor Out of Range or Frost Protection Fault

F2 error; unit may stop during cooling or show erratic coil temperature behavior (icing or short cycling).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect evaporator sensor reading, Sensor not properly attached to coil, Dirty evaporator causing abnormal temperatures, Indoor PCB misinterpreting sensor data

How to Fix / Troubleshooting

Safety: Turn off power before accessing the coil area.

Steps:

  • Clean coil and filters: Remove filters and clean them. Inspect the evaporator coil for heavy dust or ice buildup. Clean gently with a soft brush and coil cleaner if needed.
  • Check sensor attachment: Ensure the evaporator sensor is firmly clipped to the correct coil location. Reattach if loose.
  • Defrost: If the coil is iced, leave the unit off with the front panel open until all ice melts. Do not chip ice with sharp objects.
  • Replace sensor: If F2 persists and the coil is clean, replace the evaporator sensor.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Temperature Sensor (NTC)
Check Price on Amazon