H1
Royal Clima
Defrost / Preheating Indication (Protection Mode)
Indoor unit shows H1 and no warm air is produced at the beginning of heating mode.
Advertisements
Possible Causes
Outdoor unit in defrost cycle, Low outdoor temperature causing frequent defrost, Sensor readings triggering defrost protection, Software-controlled compressor delay
How to Fix / Troubleshooting
Note: On many Royal Clima heat pump models, H1 is an informational code indicating defrost or preheating, not a fault.
- Step 1 – Wait for defrost to complete: Allow 5–15 minutes for the outdoor unit to complete defrost. During this time, indoor fan may stop or blow very low air.
- Step 2 – Check outdoor unit: Ensure the outdoor coil is not completely blocked by ice or snow. Clear snow around the unit to improve airflow.
- Step 3 – Verify filters and airflow: Clean indoor filters and ensure vents are not blocked to reduce defrost frequency.
When to call a technician: If H1 remains permanently or heating never resumes, there may be a sensor or defrost control issue requiring professional diagnosis.