Royal Clima
Royal Clima Air Conditioners Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E0
Indoor unit does not respond to remote, display shows E0 and unit will not start cooling or heating.
Indoor Unit EEPROM / Main PCB Communication Error
E1
Indoor unit stops shortly after starting, display shows E1, outdoor unit does not run.
Indoor–Outdoor Communication Failure
E2
Indoor unit runs briefly then stops, display shows E2, airflow may be weak or irregular.
Indoor Evaporator Coil Freeze Protection / Anti-freeze Sensor Fault
E3
Outdoor unit stops, indoor unit may show E3 and cooling/heating stops unexpectedly.
Outdoor Unit Overcurrent / Compressor Overload Protection
E4
Unit stops during operation, indoor display shows E4, sometimes after long cooling cycles.
High Discharge Temperature / Compressor Overheating
E5
Indoor unit shows E5 and stops; sometimes the outdoor unit does not start at all.
Overvoltage / Undervoltage Protection or Power Supply Error
E6
Indoor unit shows E6, compressor may not start or stops shortly after starting.
Compressor Start Failure / Inverter Drive Fault
E7
Indoor unit shows E7, louver may not move correctly or airflow direction cannot be adjusted.
Indoor Louver Motor / Stepper Motor Fault
E8
Indoor unit shows E8, unit may stop and restart frequently, sometimes with reduced airflow.
Indoor Fan Motor Fault / Overload
E9
Indoor unit shows E9, sometimes accompanied by water leakage or unit stopping in cooling mode.
Full Drain Pan / Water Level Sensor Fault (if equipped)
F0
Indoor unit shows F0 and stops cooling; may occur shortly after startup.
Refrigerant Undercharge / Low Pressure Protection
F1
Indoor unit shows F1, unit may run but with poor temperature control.
Indoor Ambient Temperature Sensor (Room Sensor) Fault
F2
Indoor unit shows F2, unit may stop in heating mode or show unstable operation.
Indoor Evaporator Temperature Sensor Fault
F3
Indoor unit shows F3, heating performance is poor or unit stops in HEAT mode.
Outdoor Coil Temperature Sensor Fault
F4
Indoor unit shows F4, unit may stop in both cooling and heating modes.
Discharge Pipe Temperature Sensor Fault
F5
Indoor unit shows F5, outdoor fan may not run or runs erratically.
Outdoor Fan Motor Fault
F6
Indoor unit shows F6, unit may run at reduced capacity or stop intermittently.
Compressor Current Sensing / IPM Protection Fault
H0
Indoor unit shows H0, unit may not start or may operate only in fan mode.
EEPROM Parameter Error / Configuration Fault
H1
Indoor unit shows H1 and no warm air is produced at the beginning of heating mode.
Defrost / Preheating Indication (Protection Mode)
H2
Indoor unit shows H2, heating stops and may resume after some time.
High Temperature Protection in Heating / Overheat Protection
H3
Indoor unit shows H3, unit stops and may not restart until power is cycled.
Compressor Overload Protection / Overheat
H4
Indoor unit shows H4, unit may not respond to mode changes or may shut down unexpectedly.
Indoor–Outdoor Mismatch / Mode Conflict or EEPROM Error
H5
Indoor unit shows H5, unit may not start or may shut down shortly after starting.
IPM (Intelligent Power Module) Protection / Inverter Module Fault
P0
Indoor unit shows P0, compressor may not start or runs at very low capacity.
Inverter Module Protection / DC Bus Voltage Error
P1
Indoor unit shows P1, unit may stop during operation, especially under heavy load.
High or Low AC Voltage Protection
P2
Indoor unit shows P2, unit may stop cooling or heating intermittently.
Compressor Temperature Protection / Overheat
P3
Indoor unit shows P3, unit may limit capacity or shut down under extreme conditions.
Outdoor Low Temperature Protection / Anti-freeze in Heating
Symptom
Air conditioner does not turn on at all, no lights on indoor unit, remote has no effect.
No Power to Indoor Unit
Symptom
Burning or electrical smell from indoor or outdoor unit during operation.
Overheating Electrical Components
Symptom
Indoor unit blows air but there is frost or ice forming on the indoor coil or copper pipes.
Evaporator Icing
Symptom
Indoor unit fan does not run, but display is on and compressor may start (outdoor unit runs).
Indoor Fan Not Running
Symptom
Indoor unit frequently turns on and off (short cycling) without reaching set temperature.
Short Cycling / Incorrect Thermostat Sensing
Symptom
Loud rattling, buzzing, or grinding noise from indoor unit during operation.
Indoor Unit Mechanical Noise
Symptom
Loud vibration or humming from outdoor unit, sometimes transmitted into the building.
Outdoor Unit Vibration / Mounting Issue
Symptom
Outdoor fan runs but compressor does not start; no cooling or heating.
Compressor Not Starting
Symptom
Outdoor unit ices up completely in heating mode and does not defrost properly.
Defrost System Malfunction
Symptom
Poor cooling performance: room does not reach set temperature, long run times, weak cold air.
Insufficient Cooling Capacity / Performance Degradation
Symptom
Remote control does not operate the unit, but indoor display has power.
Remote Control / IR Receiver Failure
Symptom
Unit does not heat properly in HEAT mode, blows lukewarm or cold air.
Insufficient Heating Performance
Symptom
Unit powers on but compressor and outdoor fan do not start; only indoor fan runs and no cooling or heating occurs.
Outdoor Unit Not Starting
Symptom
Unpleasant musty or moldy smell from indoor unit when it starts.
Microbial Growth on Evaporator and Drain Pan
Symptom
Water dripping from outdoor unit during heating or cooling, appearing excessive to the user.
Outdoor Condensate / Defrost Water Discharge
Symptom
Water dripping from the front of the indoor unit or down the wall during cooling.
Indoor Unit Water Leakage
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E0 |
Indoor unit does not respond to remote, display shows E0 and unit will not start cooling or heating.
|
Indoor Unit EEPROM / Main PCB Communication Error | View Details |
| E1 |
Indoor unit stops shortly after starting, display shows E1, outdoor unit does not run.
|
Indoor–Outdoor Communication Failure | View Details |
| E2 |
Indoor unit runs briefly then stops, display shows E2, airflow may be weak or irregular.
|
Indoor Evaporator Coil Freeze Protection / Anti-freeze Sensor Fault | View Details |
| E3 |
Outdoor unit stops, indoor unit may show E3 and cooling/heating stops unexpectedly.
|
Outdoor Unit Overcurrent / Compressor Overload Protection | View Details |
| E4 |
Unit stops during operation, indoor display shows E4, sometimes after long cooling cycles.
|
High Discharge Temperature / Compressor Overheating | View Details |
| E5 |
Indoor unit shows E5 and stops; sometimes the outdoor unit does not start at all.
|
Overvoltage / Undervoltage Protection or Power Supply Error | View Details |
| E6 |
Indoor unit shows E6, compressor may not start or stops shortly after starting.
|
Compressor Start Failure / Inverter Drive Fault | View Details |
| E7 |
Indoor unit shows E7, louver may not move correctly or airflow direction cannot be adjusted.
|
Indoor Louver Motor / Stepper Motor Fault | View Details |
| E8 |
Indoor unit shows E8, unit may stop and restart frequently, sometimes with reduced airflow.
|
Indoor Fan Motor Fault / Overload | View Details |
| E9 |
Indoor unit shows E9, sometimes accompanied by water leakage or unit stopping in cooling mode.
|
Full Drain Pan / Water Level Sensor Fault (if equipped) | View Details |
| F0 |
Indoor unit shows F0 and stops cooling; may occur shortly after startup.
|
Refrigerant Undercharge / Low Pressure Protection | View Details |
| F1 |
Indoor unit shows F1, unit may run but with poor temperature control.
|
Indoor Ambient Temperature Sensor (Room Sensor) Fault | View Details |
| F2 |
Indoor unit shows F2, unit may stop in heating mode or show unstable operation.
|
Indoor Evaporator Temperature Sensor Fault | View Details |
| F3 |
Indoor unit shows F3, heating performance is poor or unit stops in HEAT mode.
|
Outdoor Coil Temperature Sensor Fault | View Details |
| F4 |
Indoor unit shows F4, unit may stop in both cooling and heating modes.
|
Discharge Pipe Temperature Sensor Fault | View Details |
| F5 |
Indoor unit shows F5, outdoor fan may not run or runs erratically.
|
Outdoor Fan Motor Fault | View Details |
| F6 |
Indoor unit shows F6, unit may run at reduced capacity or stop intermittently.
|
Compressor Current Sensing / IPM Protection Fault | View Details |
| H0 |
Indoor unit shows H0, unit may not start or may operate only in fan mode.
|
EEPROM Parameter Error / Configuration Fault | View Details |
| H1 |
Indoor unit shows H1 and no warm air is produced at the beginning of heating mode.
|
Defrost / Preheating Indication (Protection Mode) | View Details |
| H2 |
Indoor unit shows H2, heating stops and may resume after some time.
|
High Temperature Protection in Heating / Overheat Protection | View Details |
| H3 |
Indoor unit shows H3, unit stops and may not restart until power is cycled.
|
Compressor Overload Protection / Overheat | View Details |
| H4 |
Indoor unit shows H4, unit may not respond to mode changes or may shut down unexpectedly.
|
Indoor–Outdoor Mismatch / Mode Conflict or EEPROM Error | View Details |
| H5 |
Indoor unit shows H5, unit may not start or may shut down shortly after starting.
|
IPM (Intelligent Power Module) Protection / Inverter Module Fault | View Details |
| P0 |
Indoor unit shows P0, compressor may not start or runs at very low capacity.
|
Inverter Module Protection / DC Bus Voltage Error | View Details |
| P1 |
Indoor unit shows P1, unit may stop during operation, especially under heavy load.
|
High or Low AC Voltage Protection | View Details |
| P2 |
Indoor unit shows P2, unit may stop cooling or heating intermittently.
|
Compressor Temperature Protection / Overheat | View Details |
| P3 |
Indoor unit shows P3, unit may limit capacity or shut down under extreme conditions.
|
Outdoor Low Temperature Protection / Anti-freeze in Heating | View Details |
| – |
Air conditioner does not turn on at all, no lights on indoor unit, remote has no effect.
|
No Power to Indoor Unit | View Details |
| – |
Burning or electrical smell from indoor or outdoor unit during operation.
|
Overheating Electrical Components | View Details |
| – |
Indoor unit blows air but there is frost or ice forming on the indoor coil or copper pipes.
|
Evaporator Icing | View Details |
| – |
Indoor unit fan does not run, but display is on and compressor may start (outdoor unit runs).
|
Indoor Fan Not Running | View Details |
| – |
Indoor unit frequently turns on and off (short cycling) without reaching set temperature.
|
Short Cycling / Incorrect Thermostat Sensing | View Details |
| – |
Loud rattling, buzzing, or grinding noise from indoor unit during operation.
|
Indoor Unit Mechanical Noise | View Details |
| – |
Loud vibration or humming from outdoor unit, sometimes transmitted into the building.
|
Outdoor Unit Vibration / Mounting Issue | View Details |
| – |
Outdoor fan runs but compressor does not start; no cooling or heating.
|
Compressor Not Starting | View Details |
| – |
Outdoor unit ices up completely in heating mode and does not defrost properly.
|
Defrost System Malfunction | View Details |
| – |
Poor cooling performance: room does not reach set temperature, long run times, weak cold air.
|
Insufficient Cooling Capacity / Performance Degradation | View Details |
| – |
Remote control does not operate the unit, but indoor display has power.
|
Remote Control / IR Receiver Failure | View Details |
| – |
Unit does not heat properly in HEAT mode, blows lukewarm or cold air.
|
Insufficient Heating Performance | View Details |
| – |
Unit powers on but compressor and outdoor fan do not start; only indoor fan runs and no cooling or heating occurs.
|
Outdoor Unit Not Starting | View Details |
| – |
Unpleasant musty or moldy smell from indoor unit when it starts.
|
Microbial Growth on Evaporator and Drain Pan | View Details |
| – |
Water dripping from outdoor unit during heating or cooling, appearing excessive to the user.
|
Outdoor Condensate / Defrost Water Discharge | View Details |
| – |
Water dripping from the front of the indoor unit or down the wall during cooling.
|
Indoor Unit Water Leakage | View Details |