H2
Royal Clima High Temperature Protection in Heating / Overheat Protection

Indoor unit shows H2, heating stops and may resume after some time.

Advertisements

Possible Causes

Blocked indoor air filters, Indoor fan motor failure, Overheating of indoor coil due to low airflow, Faulty indoor coil temperature sensor

How to Fix / Troubleshooting

Safety first: Turn OFF power before cleaning or opening the unit.

  • Step 1 – Clean filters: Remove and wash the indoor air filters thoroughly. Let them dry and reinstall.
  • Step 2 – Check indoor fan: Run the unit in FAN mode and verify strong airflow. If airflow is weak or fan does not run, inspect the fan motor and blower for obstructions.
  • Step 3 – Inspect coil sensor: Ensure the indoor coil sensor is properly attached to the coil and wiring is intact.

When to call a technician: If H2 persists with clean filters and normal fan operation, a sensor or PCB fault may be present and should be checked by a technician.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Indoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements