Royal Clima Outdoor Unit Not Starting

Unit powers on but compressor and outdoor fan do not start; only indoor fan runs and no cooling or heating occurs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No power supply to outdoor unit, Loose wiring between indoor and outdoor terminals, Faulty outdoor main PCB, Failed compressor contactor (on non-inverter models)

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before inspecting wiring.

  • Step 1 – Verify outdoor power: Check that the outdoor unit receives power (dedicated breaker ON, no blown fuses).
  • Step 2 – Inspect interconnecting cable: Ensure the multi-core cable between indoor and outdoor units is correctly connected and tight at both terminal blocks.
  • Step 3 – Listen for relay click: When calling for cooling, you should hear a click from the outdoor PCB or contactor. If not, the control signal may not be reaching the outdoor unit.

When to call a technician: If wiring is correct and the outdoor unit remains dead, the outdoor PCB or compressor starter components need professional diagnosis.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Main Control PCB
Check Price on Amazon