E7
Sencor
Mode Conflict / Reversing Valve or Control Logic Error
Unit displays E7 and may not start compressor or fan correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck reversing valve coil (heat pump models), Incorrect mode command from PCB, Faulty main control PCB, Wiring fault to reversing valve
How to Fix / Troubleshooting
Safety first: Disconnect power at the breaker. The reversing valve is part of the sealed refrigeration system; do not open refrigerant lines.
- Step 1 – Reset control: Turn off power for 10 minutes, then restore and try switching between cooling and heating modes.
- Step 2 – Listen for valve shift: When changing from cool to heat, listen near the outdoor unit for a distinct click or whoosh from the reversing valve. No sound may indicate a coil or control issue.
- Step 3 – Inspect wiring: Check the wiring harness from the outdoor PCB to the reversing valve coil. Ensure connectors are tight and wires are not damaged.
- Step 4 – Coil resistance check (advanced): With power off and coil disconnected, measure coil resistance. An open circuit indicates a failed coil that must be replaced.
- Step 5 – PCB evaluation: If the coil is good but not being energized in the correct mode, the outdoor PCB may be faulty and should be replaced by a technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Reversing Valve Coil