E7
Sencor Mode Conflict / Reversing Valve or Control Logic Error

Unit displays E7 and may not start compressor or fan correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck reversing valve coil (heat pump models), Incorrect mode command from PCB, Faulty main control PCB, Wiring fault to reversing valve

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker. The reversing valve is part of the sealed refrigeration system; do not open refrigerant lines.

  • Step 1 – Reset control: Turn off power for 10 minutes, then restore and try switching between cooling and heating modes.
  • Step 2 – Listen for valve shift: When changing from cool to heat, listen near the outdoor unit for a distinct click or whoosh from the reversing valve. No sound may indicate a coil or control issue.
  • Step 3 – Inspect wiring: Check the wiring harness from the outdoor PCB to the reversing valve coil. Ensure connectors are tight and wires are not damaged.
  • Step 4 – Coil resistance check (advanced): With power off and coil disconnected, measure coil resistance. An open circuit indicates a failed coil that must be replaced.
  • Step 5 – PCB evaluation: If the coil is good but not being energized in the correct mode, the outdoor PCB may be faulty and should be replaced by a technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Reversing Valve Coil
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements