E9
Senville
Indoor Unit Full Water / Drainage Protection
Indoor unit displays E9; unit may stop and beep; sometimes associated with water leakage or full drain pan.
Advertisements
Possible Causes
Clogged condensate drain line, Blocked or kinked drain hose, Faulty float switch or water level sensor, Improper indoor unit leveling causing poor drainage
How to Fix / Troubleshooting
Safety: Turn off power and place towels or a tray under the indoor unit to catch any water.
- Step 1 – Check drain hose: Locate the condensate drain hose exiting the indoor unit. Ensure it slopes downward continuously and is not kinked or elevated.
- Step 2 – Clear clogs: Disconnect the drain hose at the indoor unit or drain point. Use a wet/dry vacuum at the hose end to suck out sludge and debris. Flush with clean water.
- Step 3 – Inspect drain pan: Remove the front cover and inspect the internal drain pan for algae, slime, or debris. Clean with a mild bleach solution (wear gloves and eye protection).
- Step 4 – Check float switch: If your Senville model has a float switch or water level sensor, ensure it moves freely and is not stuck. Clean or replace if defective.
- Step 5 – Re-level unit: Verify the indoor unit is slightly tilted toward the drain side. Adjust mounting bracket if necessary.
- Step 6 – Test: Restore power and run in COOL mode. Pour a small amount of water into the drain pan to confirm proper drainage and absence of E9.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Drain Hose
Check Price on Amazon