E1
Indoor unit displays E1 and stops cooling; fan may still run but compressor does not start.
Indoor/Outdoor Communication Failure
E2
Indoor unit shows E2 and stops cooling or heating; unit may run briefly then shut down.
Indoor Evaporator Coil Temperature Sensor (T1) Fault
E3
Indoor unit displays E3; outdoor unit may not start or shuts down shortly after starting.
Outdoor Coil Temperature Sensor (T2) Fault
E4
Indoor unit shows E4; unit may stop during heating or defrost cycles, or not enter defrost properly.
Outdoor Discharge Pipe Temperature Sensor (T3) Fault
E5
Indoor unit displays E5; compressor may not start or shuts down quickly; sometimes accompanied by humming from outdoor unit.
Overcurrent or Compressor Overload Protection
E6
Indoor unit shows E6; outdoor unit may not respond; system does not cool or heat.
Indoor-Outdoor Communication Error (Alternate Code)
E7
Indoor unit displays E7; system may not start or may run only in limited modes.
Mode Conflict or Indoor Unit/Outdoor Unit Mismatch
E8
Indoor unit shows E8; unit may shut down unexpectedly, especially in high load conditions.
Indoor Fan Motor or Overload Protection Fault
E9
Indoor unit displays E9; unit may stop and beep; sometimes associated with water leakage or full drain pan.
Indoor Unit Full Water / Drainage Protection
F0
Indoor unit displays F0; system may not cool or heat properly and may shut down.
Refrigerant System Low Charge or Underload Protection
F1
Indoor unit shows F1; unit may run but with poor temperature control or may shut down intermittently.
Indoor Ambient Temperature Sensor (Room Sensor) Fault
F2
Indoor unit displays F2; unit may freeze up or shut down unexpectedly.
Indoor Evaporator Coil Sensor (Alternate Code) Fault
F3
Indoor unit shows F3; heating performance is poor or unit stops in heating mode.
Outdoor Coil Sensor (Alternate Code) Fault
F4
Indoor unit displays F4; compressor may not start or may shut down quickly.
Compressor Discharge Temperature Sensor (Alternate Code) Fault
F5
Indoor unit shows F5; unit may stop in cooling or heating, especially under extreme outdoor temperatures.
Outdoor Ambient Temperature Sensor Fault
F6
Indoor unit displays F6; compressor may run at reduced capacity or shut down.
Indoor Fan Speed Feedback Fault
F7
Indoor unit shows F7; outdoor fan may not run or runs erratically.
Outdoor Fan Motor or Speed Feedback Fault
F8
Indoor unit displays F8; unit may stop during high load or high ambient conditions.
High Discharge Temperature Protection
F9
Indoor unit shows F9; unit may not defrost properly or may stop in heating mode.
Defrost Sensor or Defrost Protection Fault
H1
Indoor unit displays H1; heating does not start immediately, indoor fan may stop.
Defrost or Preheating Mode Indication
H3
Indoor unit shows H3; compressor stops and system shuts down to protect itself.
Compressor Overload Protection / Overheat
H4
Indoor unit displays H4; unit may not heat or cool and may shut down.
Inverter Module or Compressor Drive Fault
H5
Indoor unit shows H5; system may not start or may shut down shortly after starting.
IPM Protection or Current Sensing Fault
P0
Indoor unit displays P0; compressor may not start or may run at limited capacity.
DC Bus Voltage Protection
P1
Indoor unit shows P1; unit may stop and restart frequently.
High or Low Voltage Protection
P2
Indoor unit displays P2; unit may stop in cooling mode, especially in high humidity.
High Temperature Protection of Compressor Top or Condenser
P4
Indoor unit shows P4; compressor may not start or may shut down quickly.
Inverter Module Temperature Protection
Symptom
Indoor fan runs but compressor cycles off on very hot days; room temperature rises.
Overheating / High Pressure Shutdown
Symptom
Indoor unit blows air but airflow is very weak even on high fan speed.
Restricted Indoor Airflow
Symptom
Indoor unit display or LEDs flicker or behave erratically; unit may reset randomly.
Unstable Control Voltage or PCB Issue
Symptom
Indoor unit does not power on at all; no lights or display, remote has no effect.
No Power to Indoor Unit
Symptom
Indoor unit emits a burning or electrical smell during operation.
Overheating Electrical Component or Dust Burn-Off
Symptom
Indoor unit emits a musty or moldy odor when starting up.
Biological Growth on Evaporator Coil or Drain Pan
Symptom
Indoor unit fan does not run, but the unit powers on and responds to the remote.
Indoor Fan Motor Failure
Symptom
Indoor unit frequently turns on and off (short cycling) without reaching the set temperature.
Short Cycling / Improper Control
Symptom
Indoor unit makes a clicking or popping noise when starting or stopping.
Thermal Expansion and Plastic Casing Noise
Symptom
Indoor unit runs but does not cool well; air is only slightly cool even after 30 minutes of operation.
Reduced Cooling Capacity / Underperformance
Symptom
Indoor unit runs but does not heat well in HEAT mode; air is lukewarm and room never reaches set temperature.
Reduced Heating Capacity
Symptom
Loud humming, grinding, or metal-on-metal noise from the outdoor unit.
Outdoor Mechanical Noise
Symptom
Loud rattling or buzzing noise from the indoor unit during operation.
Indoor Unit Vibration or Loose Components
Symptom
Outdoor fan runs but compressor does not start; no cooling or heating.
Compressor Non-Start
Symptom
Outdoor unit does not start; indoor unit blows room-temperature air with no compressor or outdoor fan operation.
Outdoor Unit Non-Start
Symptom
Remote control does not operate the indoor unit, but the unit can be controlled manually (if buttons exist).
Remote Control or IR Receiver Failure
Symptom
Water dripping from the front or bottom of the indoor unit onto the wall or floor.
Indoor Unit Water Leak
Symptom
Water pooling around the base of the outdoor unit or dripping excessively from unusual locations.
Outdoor Unit Drainage or Defrost Water Issue