P4
Senville Inverter Module Temperature Protection

Indoor unit shows P4; compressor may not start or may shut down quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked airflow through outdoor electronics compartment, Failed inverter module temperature sensor, Dirty or non-functioning outdoor fan, Faulty outdoor PCB

How to Fix / Troubleshooting

Safety: Disconnect power before opening the outdoor unit.

  • Step 1 – Clean vents: Ensure the outdoor unit's electronics compartment vents are not blocked by dirt or debris.
  • Step 2 – Check outdoor fan: Confirm the fan is moving sufficient air across the coil and electronics.
  • Step 3 – Inspect sensor: Locate the inverter heat sink temperature sensor and ensure it is properly attached.
  • Step 4 – Replace sensor or PCB: If the sensor is faulty or if P4 persists, a technician may need to replace the sensor or entire PCB.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Inverter Heat Sink Temperature Sensor
Check Price on Amazon