F2
Senville Indoor Evaporator Coil Sensor (Alternate Code) Fault

Indoor unit displays F2; unit may freeze up or shut down unexpectedly.

Advertisements

Possible Causes

Defective evaporator sensor, Sensor not properly attached to coil, Broken sensor wiring, Faulty indoor PCB

How to Fix / Troubleshooting

Safety: Disconnect power before servicing.

  • Step 1 – Access coil: Remove front cover and filters to expose the evaporator coil.
  • Step 2 – Verify sensor placement: Ensure the sensor is firmly clipped to the coil tubing and not loose.
  • Step 3 – Inspect wiring and connector: Look for nicks, cuts, or pulled wires. Reseat the connector on the PCB.
  • Step 4 – Replace sensor: Install a new Senville evaporator sensor if damage is found or F2 persists.
  • Step 5 – Test: Restore power and run the unit, monitoring for normal operation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Evaporator Temperature Sensor (T1)
Check Price on Amazon

We may earn a commission from links on this page.