F2
Senville
Indoor Evaporator Coil Sensor (Alternate Code) Fault
Indoor unit displays F2; unit may freeze up or shut down unexpectedly.
Advertisements
Possible Causes
Defective evaporator sensor, Sensor not properly attached to coil, Broken sensor wiring, Faulty indoor PCB
How to Fix / Troubleshooting
Safety: Disconnect power before servicing.
- Step 1 – Access coil: Remove front cover and filters to expose the evaporator coil.
- Step 2 – Verify sensor placement: Ensure the sensor is firmly clipped to the coil tubing and not loose.
- Step 3 – Inspect wiring and connector: Look for nicks, cuts, or pulled wires. Reseat the connector on the PCB.
- Step 4 – Replace sensor: Install a new Senville evaporator sensor if damage is found or F2 persists.
- Step 5 – Test: Restore power and run the unit, monitoring for normal operation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Evaporator Temperature Sensor (T1)
Check Price on Amazon
We may earn a commission from links on this page.