F7
Senville Outdoor Fan Motor or Speed Feedback Fault

Indoor unit shows F7; outdoor fan may not run or runs erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor DC fan motor, Blocked fan blade, Loose fan motor connector, Faulty outdoor PCB fan driver

How to Fix / Troubleshooting

Safety: Shut off power at the outdoor disconnect.

  • Step 1 – Inspect fan blade: Check for debris, ice, or bent blades preventing rotation. Clear obstructions.
  • Step 2 – Spin test: With power OFF, spin the fan blade by hand. It should move freely. If stiff, the motor bearings may be failing.
  • Step 3 – Check wiring: Reseat the outdoor fan motor connector on the PCB and inspect for damage.
  • Step 4 – Replace fan motor: If the motor hums, overheats, or does not start, replace it with a Senville-compatible outdoor DC fan motor.
  • Step 5 – PCB driver: If a new motor does not fix F7, the outdoor PCB fan driver may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Fan Motor
Check Price on Amazon