F2
Soleus Air Outdoor/Condenser Fan Motor Fault (for dual-fan or split-style Soleus Air units)

Display shows F2; unit may shut down or not cool properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed condenser fan motor, Obstructed fan blade, Faulty fan capacitor or driver circuit

How to Fix / Troubleshooting

Safety: Disconnect power. Be cautious of sharp fins and fan blades.

  • Visual inspection: Access the rear or outdoor section and check if the condenser fan spins when the compressor is running. If not, proceed.
  • Check for obstructions: Remove any debris, plastic, or bent grille parts blocking the fan blade.
  • Inspect capacitor (if used): Locate the condenser fan capacitor and check for bulging or leaks. Replace with the correct Soleus Air-specified capacitor if defective.
  • Test motor: Spin the fan blade by hand; it should move freely. If seized or very rough, replace the condenser fan motor.
  • Check wiring and connectors: Ensure all motor leads are secure on the PCB or relay block.
  • Reassemble and test: After repairs, reassemble, restore power, and verify that F2 clears and the fan runs whenever the compressor is on.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements