F3
Soleus Air
Compressor Current or Overload Fault
Display shows F3; unit may not cool or may shut down shortly after startup.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Locked or failing compressor, Shorted compressor windings, Faulty compressor start components (if used)
How to Fix / Troubleshooting
Safety: Unplug the unit. Compressor and capacitor circuits can be dangerous; sealed-system work should be done by a licensed technician.
- Listen for compressor: When the unit calls for cooling, listen for a humming or clicking sound from the compressor. Rapid clicking or brief hum then stop suggests overload tripping.
- Check supply voltage: Verify correct voltage at the outlet. Low voltage can cause high current draw and F3 errors.
- Inspect wiring: With power off, check compressor terminals and wiring for burnt connectors or loose spade terminals.
- Start components: If your Soleus Air model uses a start relay or capacitor, inspect and replace if visibly damaged. Use only parts with matching ratings.
- Professional diagnosis: If F3 persists, the compressor may be internally damaged or the control board may be misreading current. Contact a professional for amp-draw testing and sealed-system evaluation.
Advertisements
Repair Difficulty
Professional Required
5/5