HI
Soleus Air
High Temperature Display / Sensor Reading Above Range
Display shows HI and unit may run continuously or struggle to reach set temperature.
Advertisements
Possible Causes
Room temperature above display range, Ambient thermistor reading too high, Thermistor located too close to warm components
How to Fix / Troubleshooting
Safety: Minimal disassembly required.
- Confirm room temperature: Use a thermometer to verify actual room temperature. If the room is extremely hot, improve ventilation and reduce heat sources.
- Check sensor placement: Ensure the ambient sensor is not touching warm metal parts or located near the condenser discharge air.
- Inspect and test sensor: If HI appears in a normal-temperature room, test the room thermistor resistance. Replace if out of specification.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Temperature Thermistor