Water Leakage / Drainage Failure
Water leaking from the front or sides of the Soleus Air window or portable AC into the room.
Advertisements
Possible Causes
Clogged condensate drain channel, Unit not tilted correctly (window models), Blocked drain hose (portable models), Excessive ice melt from frozen coil
How to Fix / Troubleshooting
Safety: Unplug the unit before tilting or opening. Avoid water contact with electrical parts.
- Check tilt (window units): Ensure the unit is slightly tilted downward toward the outside so water flows outdoors, not indoors.
- Clean drain channels: Remove the front cover and locate the condensate pan and drain holes. Use a small brush or pipe cleaner to clear any slime or debris.
- Inspect drain hose (portable): Verify that the drain hose is not kinked or blocked. Flush it with water if necessary.
- Address freezing: If you see ice on the evaporator, follow the freeze-up steps (clean filter, improve airflow, check for low refrigerant via technician).
- Dry and test: After cleaning, dry the area, reassemble, and test for leaks with a small amount of water poured into the pan while the unit is off.