GoWISE USA No heat / open heater circuit

Air fryer turns on and fan runs, but there is no heat; food remains cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open heating element coil,Tripped non-resettable thermal fuse,Loose heater wiring spade connector,Failed heater relay on main control board

How to Fix / Troubleshooting

Safety first: Unplug the unit and allow it to cool. The heater area may still be hot even if it is not working correctly.

Step-by-step checks:

  • Visual element check: Look at the heating element for breaks or heavy burn marks.
  • Access heater terminals: Remove the top or rear cover to reach the heater terminals. Check for loose or burnt connectors.
  • Thermal fuse: Locate the thermal fuse in the heater circuit. Test for continuity with a meter. If open, replace with the exact rated GoWISE-compatible fuse.
  • Element continuity: Test the heating element with a multimeter. If open, replace the heating element assembly.
  • Control board: If both fuse and element are good, the heater relay or triac on the control board may have failed, requiring board replacement.

When to stop: Do not bypass the thermal fuse. If you are unsure how to test components safely, contact a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heating Element Assembly
Check Price on Amazon