E17
ACV Room Thermostat / OpenTherm Communication Fault

Boiler displays E17, no response to room thermostat or controller

Advertisements

Possible Causes

Disconnected room thermostat, Faulty OpenTherm cable, Incorrect control parameter settings, Faulty room controller

How to Fix / Troubleshooting

Safety first: Isolate power before altering control wiring.

  • Check controller power: Ensure the ACV room controller or thermostat has power (screen on, batteries good).
  • Verify demand: Set the room thermostat to a higher temperature than the room. Confirm it is actually calling for heat.
  • Inspect wiring: Check that the low-voltage control wires are firmly connected at both the boiler and the controller. Look for damage or signs of rodents.
  • Parameter check: On the boiler menu, confirm that the control mode (e.g., On/Off, OpenTherm, ACV controller) matches the installed device. Refer to the ACV manual.
  • Professional help: If E17 persists, a technician should test the controller and boiler interface circuits.