E21
ACV Return Temperature Too High / Low Delta-T

Boiler displays E21, burner output limited, may be linked to return temperature too high

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Oversized boiler for system, Pump speed too high, Bypassed flow (automatic bypass valve stuck open), Undersized system circuit

How to Fix / Troubleshooting

Safety first: Allow system to cool before adjusting valves.

  • Check bypass valve: If an automatic bypass valve is installed near the ACV boiler, ensure it is not fully open. It should be set according to system design (usually by a technician).
  • Open radiators: Ensure enough radiators or heating circuits are open to absorb boiler output.
  • Controller settings: Lower the maximum flow temperature on the boiler to reduce stress on the system.
  • Professional balancing: A technician should balance the system, adjust pump speed, and set the bypass correctly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Automatic Bypass Valve
Check Price on Amazon