E10
Atlantic Insufficient Circulation / Flow Switch Fault

Boiler shows E10 and stops; may occur during operation or at startup, often with gurgling noises in the boiler.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked primary circuit, Stuck or failed flow switch, Airlock in boiler heat exchanger, Pump not running at correct speed

How to Fix / Troubleshooting

Safety: Turn off power and allow the boiler to cool before bleeding or opening any components.

  • Bleed the boiler and radiators: Use the automatic air vent (if fitted) or manual bleed points on the boiler and radiators to remove trapped air.
  • Check pump speed setting: Some Atlantic pumps have adjustable speed. Ensure it is not set to the lowest setting if the system requires higher flow.
  • Clean system filter: If a filter is installed on the return, isolate and clean it to restore flow.
  • Professional service: A technician should test the flow switch or flow sensor, verify pump performance, and flush the primary heat exchanger if blocked.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Switch / Flow Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements