Atlantic
Atlantic Boilers Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
E01
Boiler does not ignite, burner does not start, display shows E01 shortly after a heating or hot water demand.
Ignition Failure / Flame Not Detected
E02
Boiler locks out with E02, burner stops shortly after ignition or during operation, sometimes accompanied by rumbling or popping noises.
Flame Loss During Operation
E03
Boiler attempts to start but shuts down with E03, fan may run briefly, no ignition noise heard.
Air Pressure Switch / Fan Combustion Circuit Fault
E04
Boiler stops and displays E04, often after running for a short time; casing may feel very hot, radiators may be partially warm.
Primary Circuit Overheat / Safety Thermostat Trip
E05
Boiler shows E05, will not start heating; may occur immediately on power-up or when a heating demand is present.
Flow Temperature Sensor (NTC) Fault
E06
Boiler displays E06, domestic hot water (DHW) may not function correctly or temperature fluctuates.
DHW Temperature Sensor (NTC) Fault
E07
Boiler locks out with E07, often associated with very high temperature readings or rapid cycling.
Return Temperature Sensor (NTC) Fault
E08
Boiler shows E08 and will not start; may be accompanied by low or zero pressure reading on the gauge.
Low Water Pressure / Pressure Switch Fault
E09
Boiler displays E09, may attempt to start but shuts down quickly; sometimes accompanied by unusual fan noise.
Fan Speed / Fan Feedback Fault
E10
Boiler shows E10 and stops; may occur during operation or at startup, often with gurgling noises in the boiler.
Insufficient Circulation / Flow Switch Fault
E11
Boiler displays E11, no hot water in combi mode, heating may still work.
DHW Flow Detection Fault
E12
Boiler shows E12, will not start; may be intermittent, often after power cuts or surges.
Control PCB Communication / Internal Error
E13
Boiler displays E13, may continue to run at reduced performance or shut down depending on model.
Flue Gas Temperature Sensor Fault / Overtemperature
E14
Boiler shows E14, often associated with frequent on/off cycling and unstable temperatures.
Modulation / Gas Valve Control Fault
E15
Boiler displays E15, may not respond to user inputs or may behave erratically.
User Interface / Keypad Fault
E16
Boiler shows E16, often related to external control issues; heating may not start even though the boiler appears powered.
Room Thermostat / External Control Fault
E17
Boiler displays E17, may be associated with very low return temperatures or cold radiators.
Condensing / Return Temperature Protection Fault
E18
Boiler shows E18, often during DHW operation, with very hot water or sudden shutdown.
DHW Overtemperature / Anti-Scald Protection
E19
Boiler displays E19, may not start or may shut down unexpectedly; sometimes after brownouts or unstable mains.
Power Supply / Low Voltage Fault
E20
Boiler shows E20, often associated with condensate issues or flue-related lockouts.
Condensate Drain / Siphon Fault
E21
Boiler displays E21, may be linked to incorrect sensor readings or inconsistent operation.
Sensor Calibration / Out-of-Range Fault
E22
Boiler shows E22, often when using advanced Atlantic controls or remote connectivity.
Communication Fault with External Module
E23
Boiler displays E23, may shut down or limit output; sometimes associated with sensor wiring damage.
Short Circuit on Sensor or Low-Voltage Circuit
E24
Boiler shows E24, often after overheating events or repeated lockouts.
Manual Reset Safety Thermostat Tripped
E25
Boiler displays E25, may be associated with incorrect configuration or incompatible accessories.
Configuration / Parameter Error
Symptom
Boiler does not start at all, no lights or display, as if completely dead.
No Power / Dead Boiler
Symptom
Boiler emits a burning smell or plastic smell during operation, with or without visible smoke.
Overheating Electrical Component
Symptom
Boiler flue terminal outside shows white staining or dripping water, and there may be damp patches on the wall near the flue.
Condensate / Flue Condensation Issue
Symptom
Boiler frequently loses pressure and needs to be topped up every few days, no visible leaks and no error code most of the time.
Chronic Pressure Loss
Symptom
Boiler frequently trips the electrical breaker or blows fuses when starting or during operation.
Electrical Short or Overload
Symptom
Boiler ignites with a loud bang or pop (delayed ignition) when starting.
Delayed Ignition
Symptom
Boiler is very noisy, with humming, grinding, or rattling sounds during operation, but continues to run.
Mechanical Noise / Vibration
Symptom
Boiler leaking water from underneath the casing or from pipe connections, no specific error code displayed.
Internal Water Leak
Symptom
Boiler makes loud banging or knocking noises (kettling) during operation, especially when heating starts or stops.
Kettling / Localized Boiling in Heat Exchanger
Symptom
Boiler runs but radiators remain cold or only lukewarm, while the boiler flow pipe is hot.
Poor Heating Circulation
Symptom
Boiler runs continuously and overheats the house even when the room thermostat is turned down or off.
Boiler Not Responding to Room Thermostat
Symptom
Boiler starts then shuts down after a few seconds without showing an error code, heating and hot water are unreliable.
Short Cycling / Unstable Operation
Symptom
Boiler works for heating but not for domestic hot water (or vice versa), with no error code displayed.
Diverter Valve / Hydraulic Selector Fault
Symptom
Domestic hot water temperature fluctuates between hot and cold during a shower, with no error code.
Inconsistent DHW Temperature
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| E01 |
Boiler does not ignite, burner does not start, display shows E01 shortly after a heating or hot water demand.
|
Ignition Failure / Flame Not Detected | View Details |
| E02 |
Boiler locks out with E02, burner stops shortly after ignition or during operation, sometimes accompanied by rumbling or popping noises.
|
Flame Loss During Operation | View Details |
| E03 |
Boiler attempts to start but shuts down with E03, fan may run briefly, no ignition noise heard.
|
Air Pressure Switch / Fan Combustion Circuit Fault | View Details |
| E04 |
Boiler stops and displays E04, often after running for a short time; casing may feel very hot, radiators may be partially warm.
|
Primary Circuit Overheat / Safety Thermostat Trip | View Details |
| E05 |
Boiler shows E05, will not start heating; may occur immediately on power-up or when a heating demand is present.
|
Flow Temperature Sensor (NTC) Fault | View Details |
| E06 |
Boiler displays E06, domestic hot water (DHW) may not function correctly or temperature fluctuates.
|
DHW Temperature Sensor (NTC) Fault | View Details |
| E07 |
Boiler locks out with E07, often associated with very high temperature readings or rapid cycling.
|
Return Temperature Sensor (NTC) Fault | View Details |
| E08 |
Boiler shows E08 and will not start; may be accompanied by low or zero pressure reading on the gauge.
|
Low Water Pressure / Pressure Switch Fault | View Details |
| E09 |
Boiler displays E09, may attempt to start but shuts down quickly; sometimes accompanied by unusual fan noise.
|
Fan Speed / Fan Feedback Fault | View Details |
| E10 |
Boiler shows E10 and stops; may occur during operation or at startup, often with gurgling noises in the boiler.
|
Insufficient Circulation / Flow Switch Fault | View Details |
| E11 |
Boiler displays E11, no hot water in combi mode, heating may still work.
|
DHW Flow Detection Fault | View Details |
| E12 |
Boiler shows E12, will not start; may be intermittent, often after power cuts or surges.
|
Control PCB Communication / Internal Error | View Details |
| E13 |
Boiler displays E13, may continue to run at reduced performance or shut down depending on model.
|
Flue Gas Temperature Sensor Fault / Overtemperature | View Details |
| E14 |
Boiler shows E14, often associated with frequent on/off cycling and unstable temperatures.
|
Modulation / Gas Valve Control Fault | View Details |
| E15 |
Boiler displays E15, may not respond to user inputs or may behave erratically.
|
User Interface / Keypad Fault | View Details |
| E16 |
Boiler shows E16, often related to external control issues; heating may not start even though the boiler appears powered.
|
Room Thermostat / External Control Fault | View Details |
| E17 |
Boiler displays E17, may be associated with very low return temperatures or cold radiators.
|
Condensing / Return Temperature Protection Fault | View Details |
| E18 |
Boiler shows E18, often during DHW operation, with very hot water or sudden shutdown.
|
DHW Overtemperature / Anti-Scald Protection | View Details |
| E19 |
Boiler displays E19, may not start or may shut down unexpectedly; sometimes after brownouts or unstable mains.
|
Power Supply / Low Voltage Fault | View Details |
| E20 |
Boiler shows E20, often associated with condensate issues or flue-related lockouts.
|
Condensate Drain / Siphon Fault | View Details |
| E21 |
Boiler displays E21, may be linked to incorrect sensor readings or inconsistent operation.
|
Sensor Calibration / Out-of-Range Fault | View Details |
| E22 |
Boiler shows E22, often when using advanced Atlantic controls or remote connectivity.
|
Communication Fault with External Module | View Details |
| E23 |
Boiler displays E23, may shut down or limit output; sometimes associated with sensor wiring damage.
|
Short Circuit on Sensor or Low-Voltage Circuit | View Details |
| E24 |
Boiler shows E24, often after overheating events or repeated lockouts.
|
Manual Reset Safety Thermostat Tripped | View Details |
| E25 |
Boiler displays E25, may be associated with incorrect configuration or incompatible accessories.
|
Configuration / Parameter Error | View Details |
| – |
Boiler does not start at all, no lights or display, as if completely dead.
|
No Power / Dead Boiler | View Details |
| – |
Boiler emits a burning smell or plastic smell during operation, with or without visible smoke.
|
Overheating Electrical Component | View Details |
| – |
Boiler flue terminal outside shows white staining or dripping water, and there may be damp patches on the wall near the flue.
|
Condensate / Flue Condensation Issue | View Details |
| – |
Boiler frequently loses pressure and needs to be topped up every few days, no visible leaks and no error code most of the time.
|
Chronic Pressure Loss | View Details |
| – |
Boiler frequently trips the electrical breaker or blows fuses when starting or during operation.
|
Electrical Short or Overload | View Details |
| – |
Boiler ignites with a loud bang or pop (delayed ignition) when starting.
|
Delayed Ignition | View Details |
| – |
Boiler is very noisy, with humming, grinding, or rattling sounds during operation, but continues to run.
|
Mechanical Noise / Vibration | View Details |
| – |
Boiler leaking water from underneath the casing or from pipe connections, no specific error code displayed.
|
Internal Water Leak | View Details |
| – |
Boiler makes loud banging or knocking noises (kettling) during operation, especially when heating starts or stops.
|
Kettling / Localized Boiling in Heat Exchanger | View Details |
| – |
Boiler runs but radiators remain cold or only lukewarm, while the boiler flow pipe is hot.
|
Poor Heating Circulation | View Details |
| – |
Boiler runs continuously and overheats the house even when the room thermostat is turned down or off.
|
Boiler Not Responding to Room Thermostat | View Details |
| – |
Boiler starts then shuts down after a few seconds without showing an error code, heating and hot water are unreliable.
|
Short Cycling / Unstable Operation | View Details |
| – |
Boiler works for heating but not for domestic hot water (or vice versa), with no error code displayed.
|
Diverter Valve / Hydraulic Selector Fault | View Details |
| – |
Domestic hot water temperature fluctuates between hot and cold during a shower, with no error code.
|
Inconsistent DHW Temperature | View Details |