E20
Atlantic Condensate Drain / Siphon Fault

Boiler shows E20, often associated with condensate issues or flue-related lockouts.

Advertisements

Possible Causes

Blocked condensate trap, Frozen condensate pipe, Incorrect condensate pipe fall, Siphon not primed

How to Fix / Troubleshooting

Safety: Condensate is mildly acidic. Wear gloves and eye protection when handling.

  • Check external condensate pipe: Look for kinks, sagging, or freezing (white frost) on the plastic pipe leading outside or to a drain.
  • Thaw frozen pipe: Pour warm (not boiling) water over the frozen section until thawed. Insulate the pipe to prevent recurrence.
  • Clean condensate trap: Isolate power, remove the trap beneath the boiler, empty and rinse it, then refit ensuring seals are correct.
  • Prime the trap: Pour a small amount of clean water into the trap to ensure the siphon is filled before restarting.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Trap and Pipe
Check Price on Amazon

We may earn a commission from links on this page.