E119
Baxi
Low System Pressure Lockout
Boiler displays E119, pressure gauge low, boiler will not fire
Advertisements
Possible Causes
Water leak in heating circuit, Recently bled radiators without repressurising, Faulty pressure sensor on Baxi boiler, Expansion vessel losing charge causing pressure swings
How to Fix / Troubleshooting
Safety first: Let the system cool before topping up.
Step-by-step repressurising:
- Locate the pressure gauge and confirm it is below 1.0 bar.
- Find the filling loop (flexible hose with two valves). Open the valves slowly until the gauge reaches 1.2–1.5 bar.
- Close both valves fully and remove the filling loop if it is detachable.
- Reset the boiler and check for normal operation.
- Inspect for visible leaks around radiators, valves, and under the boiler.
If E119 recurs frequently:
- Contact a heating engineer to check the expansion vessel, pressure sensor, and for hidden leaks.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
System Pressure Sensor
Check Price on Amazon