Baxi

Baxi Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Boiler will not ignite, display shows E01, no flame symbol, heating and hot water not working
Ignition Lockout / Flame Failure
E02
Boiler locks out with E02, overheats and shuts down, may make kettling noises before stopping
Primary Heat Exchanger Overheat / Safety Thermostat Trip
E03
Boiler shows E03 and will not fire, fan may start briefly then stop
Flue Fan / Air Pressure Switch Fault
E04
Boiler displays E04, no ignition, may attempt to start then lock out
Flame Detection Fault / Ionisation Failure
E05
Boiler shows E05, heating and hot water unavailable, temperature reading may be erratic
Flow Temperature Sensor (NTC) Fault
E06
Boiler displays E06, domestic hot water temperature unstable or not recognised
DHW Temperature Sensor (NTC) Fault
E09
Boiler shows E09 and locks out, no heating or hot water
Gas Valve / Burner Control Fault
E10
Boiler displays E10, pressure gauge may be low or flashing, boiler will not run
Low Water Pressure / System Pressure Fault
E11
Boiler shows E11, often associated with fan or flue issues, no ignition
Air Pressure Switch / Flue Safety Fault
E119
Boiler displays E119, pressure gauge low, boiler will not fire
Low System Pressure Lockout
E12
Boiler intermittently locks out with E12, may relate to sensor or PCB communication issues
Internal Communication / Sensor Circuit Fault
E13
Boiler shows E13, often associated with flue gas temperature or sensor issues
Flue Gas Temperature Sensor Fault / Overtemperature
E133
Boiler shows E133, no ignition, may have tried to light several times, often after gas supply interruption
Ignition Lockout / Gas Supply Fault
E16
Boiler displays E16, often related to return temperature sensing or differential issues
Return Temperature Sensor (NTC) Fault
E160
Boiler displays E160, often associated with fan or PCB fault, no ignition
Fan / PCB Communication Fault
E168
Boiler shows E168, often described as a general PCB or power supply fault, intermittent lockouts
PCB / Power Supply Fault
E193
Boiler displays E193, often related to circulation or pump speed issues
Pump Speed / Flow Detection Fault
E20
Boiler shows E20, often associated with pump or circulation problems
Circulation Fault / Pump Error
E25
Boiler intermittently locks out with E25, often during heating demand, may be accompanied by noisy operation
Primary Circuit Overheat / Flow Restriction
E270
Boiler shows E270, often associated with sensor calibration or configuration issues
Configuration / Sensor Calibration Fault
E28
Boiler shows E28, often related to flue or condensate issues, no ignition
Blocked Condensate / Flue Safety Lockout
E40
Boiler displays E40, often associated with external controls or communication faults
External Control / Bus Communication Error
E50
Boiler shows E50, often related to fan speed or modulation control
Fan Speed Control / Modulation Fault
E53
Boiler intermittently locks out with E53, may relate to gas valve modulation or flame stability
Gas Valve Modulation / Combustion Control Fault
E60
Boiler shows E60, often associated with flue or condensate safety chain
General Flue / Condensate Safety Fault
Symptom
Boiler cycles on and off rapidly, never runs for long, rooms take a long time to heat
Short Cycling / Oversized Boiler or Control Issue
Symptom
Boiler display is blank, no lights or response, but mains power is present at the property
No Power to Boiler / Internal Fuse or PCB Failure
Symptom
Boiler does not fire for hot water unless heating is also on (combi boiler)
DHW Flow Detection / Diverter Valve Fault
Symptom
Boiler does not respond to room thermostat, heating will not come on even though hot water works
External Control / Thermostat Fault
Symptom
Boiler frequently loses pressure without visible leaks, pressure rises when hot then drops when cold
Expansion Vessel Failure / PRV Discharge
Symptom
Boiler frequently trips the electrical circuit breaker or blows the fuse
Electrical Short / Overcurrent
Symptom
Boiler leaking water from underneath the casing or pipe connections
Internal Water Leak
Symptom
Boiler locks out occasionally during very cold weather, external condensate pipe is icy
Frozen Condensate Pipe
Symptom
Boiler makes a loud humming or vibrating noise when firing
Resonance / Fan or Burner Vibration
Symptom
Boiler makes loud banging or knocking noises (kettling) when heating is on
Kettling / Localised Boiling in Heat Exchanger
Symptom
Boiler or flue area smells of gas or combustion fumes when running
Gas Leak / Flue Gas Escape
Symptom
Boiler runs but radiators upstairs are hot while downstairs remain cold (or vice versa)
Partial Circulation / Airlock or Balancing Issue
Symptom
Condensate pipe dripping heavily or gurgling noises from boiler during operation
Condensate Drainage Issue
Symptom
Hot water runs hot then cold or fluctuates in temperature when taps are used
DHW Temperature Instability
Symptom
Radiators not getting hot or only partially warm while boiler appears to run
Poor Circulation / System Balancing Issue