Beretta Fan Overrun / Stuck Relay

Boiler fan runs continuously even when there is no demand for heating or hot water.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

PCB fan relay stuck closed, Faulty flue temperature sensor keeping fan on, Control logic error in PCB

How to Fix / Troubleshooting

Safety: Isolate power before accessing the PCB.

  • Check demand indicators: Ensure there is no call for heat or hot water from controls.
  • Power reset: Turn off the Beretta boiler at the mains for several minutes, then restore power and observe if the fan stops.
  • Technician – PCB inspection: Check the fan relay on the PCB for signs of sticking or burning. Replace the PCB if the relay is faulty.
  • Check flue sensor: Verify the flue NTC is not falsely indicating high temperature.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements