A07
Beretta Flue Gas Overtemperature / Flue Thermostat Intervention

Boiler displays A07, no heating or hot water, fan may not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked or restricted flue, Faulty flue thermostat or flue NTC sensor, Fan not running or running at low speed, Incorrect flue installation causing recirculation of flue gases

How to Fix / Troubleshooting

Safety: Turn off the boiler and do not attempt to operate it with a suspected flue fault. Risk of carbon monoxide exposure.

  • Check flue terminal outside: Ensure the terminal is not blocked by vegetation, plastic bags, snow, or other obstructions.
  • Visual inspection: Check that the flue is properly supported, not sagging, and that all joints appear secure. Do not dismantle room-sealed flues unless qualified.
  • Technician – test fan operation: Verify that the fan starts and reaches correct speed. Replace the Beretta fan assembly if it fails to run or is noisy and slow.
  • Technician – check flue thermostat/NTC: Measure resistance and continuity of the flue temperature sensor or thermostat. Replace if it trips prematurely or is open circuit.
  • Flue system check: A Gas Safe engineer should inspect the entire flue route for blockages, incorrect slopes, or recirculation issues and rectify as required.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Flue Temperature Sensor
Check Price on Amazon