A16
Beretta
Heating Flow Sensor / Circuit Fault
Boiler shows A16, no heating, hot water may still function depending on model.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty heating flow NTC sensor, Broken wiring to flow sensor, PCB input fault for CH circuit
How to Fix / Troubleshooting
Safety: Isolate power before working inside the boiler.
- Check mode: Test both heating and hot water. Note if A16 appears only on heating demand.
- Technician – inspect flow NTC: Locate the CH flow NTC on the Beretta boiler flow pipe. Check connection and measure resistance.
- Check harness: Inspect the cable from the flow NTC to the PCB for damage or loose connectors.
- PCB check: If sensor and wiring are sound, the main PCB may require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow NTC Sensor