A20
Beretta
Circulation Pump Fault / Pump Feedback Error
Boiler shows A20, no heating, pump may run briefly then stop.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Seized or failed pump motor, Air lock in pump, Pump wiring fault, PCB not supplying power to pump
How to Fix / Troubleshooting
Safety: Isolate power before touching the pump. Water may be hot.
- Listen for pump: On a heating demand, listen for pump operation. A humming noise without flow suggests a stuck rotor.
- Free pump rotor: With power off, remove the pump vent screw and gently turn the shaft with a screwdriver. Refit screw and test.
- Bleed pump: Allow air to escape from the pump via the vent screw until water appears.
- Technician – electrical tests: Check for correct voltage at the pump terminals when there is a call for heat. If present and pump does not run, replace the Beretta pump. If absent, suspect the PCB.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.