Buderus
Insufficient DHW Output
Boiler runs but hot water is only lukewarm
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled plate heat exchanger, Gas valve not opening fully, Incorrect DHW temperature setting, Flow rate too high for boiler capacity
How to Fix / Troubleshooting
Safety: Beware of sudden temperature changes when testing DHW.
- 1. Check DHW setpoint: Verify the domestic hot water temperature setting on the Buderus control panel and increase if necessary within safe limits.
- 2. Reduce flow: Partially close the hot tap to reduce flow and see if temperature increases, indicating a capacity or scaling issue.
- 3. Clean inlet filter: Ensure stable inlet pressure by cleaning the cold water filter.
- 4. Plate heat exchanger: Have a technician descale or replace the DHW plate heat exchanger if scaling is suspected.
- 5. Gas valve and combustion: A technician should verify that the boiler reaches full DHW output and that gas settings are correct.