Buderus Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
A11
Boiler displays A11 and will not ignite; fan may run briefly
Ionisation / Flame Detection Fault
A21
Boiler shows A21; burner stops and may not restart
Flow Sensor / Flow Switch Fault (DHW or system flow)
A3
Boiler displays A3 and shuts down; may be accompanied by overheating or rapid temperature rise
Safety Temperature Limiter (STB) Tripped / Overheat Protection
A4
Boiler shows A4 and will not start; may occur after power interruption or service work
Low Water Pressure / Water Shortage
A41
Boiler displays A41; may run at reduced output or shut down
Supply Voltage Out of Range
A5
Boiler displays A5; burner stops and may restart intermittently
Flue Gas Temperature Sensor Fault / Overtemperature
A51
Boiler shows A51; fan may run but burner does not ignite
Air Pressure Switch / Fan Speed Fault
A6
Boiler shows A6; may run at reduced output or shut down
Outside Temperature Sensor Fault (Weather Compensation)
A61
Boiler displays A61; burner shuts down unexpectedly during operation
Flame Loss During Operation
A7
Boiler does not ignite; display shows A7 shortly after a call for heat or hot water
Flow Temperature Sensor Fault
A70
Boiler shows A70; heating curve or room temperature control not functioning correctly
Room Thermostat / Room Sensor Communication Fault
A8
Boiler locks out with A8; burner does not start or shuts down quickly after ignition attempt
Return Temperature Sensor Fault
A9
Boiler shows A9 and stops; may occur during operation or at startup
DHW Temperature Sensor Fault
A90
Boiler displays A90; communication with external control or cascade manager fails
BUS Communication Fault (e.g., Logamatic, cascade control)
E2
Boiler shows E2 and locks out; no ignition
Ignition Failure
E3
Boiler displays E3; burner shuts down due to overheating
Primary Flow Overtemperature
E9
Boiler shows E9; often associated with low water content or dry firing
Water Shortage / Dry-Fire Protection
H1
Boiler displays H1; burner does not start, fan may run
Fan Fault / Fan Speed Too Low
H4
Boiler shows H4; burner shuts down, often with flue-related issues
Flue Gas Sensor Overtemperature / Blocked Flue
H6
Boiler displays H6; burner output limited or boiler shuts down
Return Temperature Too High / Poor Heat Dissipation
H7
Boiler shows H7; DHW performance reduced or intermittent
DHW Flow Rate Too Low / DHW Sensor or Flow Fault
U9
Boiler displays U9; control functions limited or locked
Parameter / Configuration Error
Symptom
Boiler cycles on and off rapidly without reaching set temperature
Short Cycling
Symptom
Boiler display is dim, flickering, or unreadable
Display / User Interface Fault
Symptom
Boiler display is on but there is no response to heating or hot water demand
Control / Demand Signal Fault
Symptom
Boiler emits a burning smell or plastic smell during operation
Overheating Electrical or Plastic Component
Symptom
Boiler frequently locks out and requires manual reset, with varying error codes or none displayed
Intermittent Lockout / Unstable Operation
Symptom
Boiler frequently loses pressure and needs topping up
Chronic Pressure Loss
Symptom
Boiler is very noisy (whistling, roaring, or droning) when firing
Combustion Noise / Resonance
Symptom
Boiler leaking water from underneath the casing
Internal Water Leak
Symptom
Boiler makes loud banging or knocking noises (kettling) during operation
Heat Exchanger Kettling / Local Boiling
Symptom
Boiler room or flue area shows signs of soot or black staining
Incomplete Combustion / Sooting
Symptom
Boiler runs but hot water is only lukewarm
Insufficient DHW Output
Symptom
Boiler runs but radiators stay cold or only lukewarm
Poor Circulation / Heating Circuit Flow Problem
Symptom
Boiler shuts down when a particular zone or underfloor circuit operates
Hydraulic Imbalance / Local Flow Restriction
Symptom
Boiler will not start at all; no display or lights
No Power / Dead Boiler
Symptom
Condensate water backs up or boiler shuts down in freezing weather
Blocked or Frozen Condensate Drain
Symptom
Domestic hot water temperature fluctuates between hot and cold
Unstable DHW Temperature Control
Symptom
Radiators get hot even when there is no call for heating
Unwanted Heating / Valve Bypass