A51
Buderus Air Pressure Switch / Fan Speed Fault

Boiler shows A51; fan may run but burner does not ignite

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked flue or air intake, Faulty air pressure switch, Damaged or disconnected silicone tubes, Fan not reaching required speed

How to Fix / Troubleshooting

Safety: Turn off gas and power. Do not operate the boiler with suspected flue or air path blockage.

  • 1. Check flue terminal: Ensure the Buderus concentric flue terminal is clear of obstructions outside.
  • 2. Inspect condensate system: A blocked condensate trap can flood the combustion chamber and affect the fan/APS. Clean the trap and ensure free drainage.
  • 3. Air pressure switch tubes: Open the boiler front panel and locate the air pressure switch. Check the silicone tubes to the fan/combustion chamber for splits, kinks, or water. Drain any condensate and refit securely.
  • 4. Test fan operation: When there is a heat demand, listen for the fan. If it does not start or is very noisy, the fan motor may be failing.
  • 5. Switch test: A technician can test the air pressure switch contacts with a multimeter while the fan runs. If the switch does not change state, replace it.
  • 6. Control board: If the fan and switch are good but A51 persists, the control board may not be reading the signal correctly and may need replacement.