A51
Buderus
Air Pressure Switch / Fan Speed Fault
Boiler shows A51; fan may run but burner does not ignite
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked flue or air intake, Faulty air pressure switch, Damaged or disconnected silicone tubes, Fan not reaching required speed
How to Fix / Troubleshooting
Safety: Turn off gas and power. Do not operate the boiler with suspected flue or air path blockage.
- 1. Check flue terminal: Ensure the Buderus concentric flue terminal is clear of obstructions outside.
- 2. Inspect condensate system: A blocked condensate trap can flood the combustion chamber and affect the fan/APS. Clean the trap and ensure free drainage.
- 3. Air pressure switch tubes: Open the boiler front panel and locate the air pressure switch. Check the silicone tubes to the fan/combustion chamber for splits, kinks, or water. Drain any condensate and refit securely.
- 4. Test fan operation: When there is a heat demand, listen for the fan. If it does not start or is very noisy, the fan motor may be failing.
- 5. Switch test: A technician can test the air pressure switch contacts with a multimeter while the fan runs. If the switch does not change state, replace it.
- 6. Control board: If the fan and switch are good but A51 persists, the control board may not be reading the signal correctly and may need replacement.