E07
Dettson
Flow Switch / Flow Sensor Fault
Boiler displays E07 and will not fire even though system pressure is normal
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck Dettson flow switch, Blocked internal strainer, Air lock in boiler, Faulty flow sensor wiring
How to Fix / Troubleshooting
Safety: Turn off power and allow the boiler to cool before opening any water connections.
- Bleed air: Air trapped in the boiler or near the flow sensor can prevent proper operation. Bleed air from high points in the system and from the boiler's built-in air vent if present.
- Check circulator operation: Confirm the Dettson primary circulator pump is running during a call for heat. If not, the flow sensor may not detect movement. A technician may need to replace the pump or relay.
- Inspect flow switch/sensor: Locate the Dettson flow switch or turbine sensor on the boiler's water path. Check for loose wiring and secure connectors. Some models have a removable strainer that can be cleaned of debris.
- Reset and test: After clearing air and cleaning strainers, reset the boiler and observe if E07 clears. If the code returns, the flow switch/sensor itself may be defective and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Dettson flow switch / flow sensor
Check Price on Amazon