Dettson

Dettson Boilers Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Boiler will not start; control shows E01 and burner never lights
Ignition Failure Lockout
E02
Boiler attempts to start but shuts down quickly with E02 displayed
Flame Detection Failure
E03
Boiler locks out with E03; fan runs but burner does not light
Air Pressure Switch / Combustion Air Fault
E04
Boiler shuts down with E04 and will not restart until reset
High Limit Temperature Lockout
E05
Boiler displays E05 and does not respond to thermostat calls
Low Water Pressure / Low System Fill
E06
Boiler shows E06 and shuts down shortly after starting
Return Temperature Sensor Fault
E07
Boiler displays E07 and will not fire even though system pressure is normal
Flow Switch / Flow Sensor Fault
E08
Boiler shows E08 and fan does not start during a call for heat
Combustion Fan / Blower Fault
E09
Boiler locks out with E09 after several failed ignition attempts
Gas Valve / Gas Supply Fault
E10
Boiler shows E10 and shuts down during operation, often with hot supply temperature
Supply Temperature Sensor Fault
E11
Boiler displays E11 and will not respond to thermostat or control inputs
Communication / Control Board Fault
E12
Boiler shows E12 and shuts down shortly after ignition, often with noisy combustion
Flue Gas Overtemperature / Flue Sensor Fault
E13
Boiler displays E13 and will not start; condensate present around unit
Condensate Drain Fault
E14
Boiler shows E14 and cycles on and off rapidly without satisfying heat demand
Short Cycling / Minimum Run Time Fault
E15
Boiler displays E15 and domestic hot water (DHW) priority is not functioning correctly
DHW Sensor / Priority Fault
E16
Boiler shows E16 and indicates outdoor sensor error on the display
Outdoor Temperature Sensor Fault
E17
Boiler displays E17 and indicates pump or circulation error
Primary Pump Fault
E18
Boiler shows E18 and indicates sensor mismatch or configuration error
Sensor Configuration / Parameter Fault
E19
Boiler displays E19 and indicates internal memory or parameter error
Control Memory / EEPROM Fault
E20
Boiler shows E20 and indicates flame present when there should be none
False Flame Detection
Symptom
Boiler cabinet vibrates excessively during operation
Mechanical Vibration / Imbalance
Symptom
Boiler display is on but unresponsive to buttons or menu navigation
User Interface / Keypad Failure
Symptom
Boiler emits a strong gas smell near the unit, especially before ignition
Gas Leak / Delayed Ignition
Symptom
Boiler frequently loses pressure and needs to be topped up
Chronic Pressure Loss
Symptom
Boiler frequently trips the household circuit breaker or blows fuses
Electrical Overload / Short Circuit
Symptom
Boiler is very noisy; fan whines or rattles loudly during operation
Combustion Fan / Blower Noise
Symptom
Boiler leaking water from bottom of cabinet
Internal Water Leak
Symptom
Boiler makes gurgling or trickling water sounds inside the cabinet
Air in Boiler / Inadequate Air Separation
Symptom
Boiler makes loud banging or knocking noises when starting or stopping
Water Hammer / Kettling
Symptom
Boiler operates but house does not reach set temperature in cold weather
Underheating / Capacity or Control Issue
Symptom
Boiler pressure rises excessively during heating and relief valve opens
Overpressure During Operation
Symptom
Boiler produces a burning or electrical smell during operation
Overheating Electrical Component
Symptom
Boiler runs but some radiators or zones stay cold
Poor Circulation / Air Lock
Symptom
Boiler runs continuously and overshoots the thermostat setting
Control / Thermostat Overshoot
Symptom
Boiler short cycles on domestic hot water; hot water temperature fluctuates
DHW Temperature Instability
Symptom
Boiler starts but shuts down after a few seconds without showing a code
Soft Lockout / Safety Interruption
Symptom
Boiler vent terminal outside shows signs of sooting or black staining
Poor Combustion / Sooting
Symptom
Boiler will not start; display is blank and no lights are on
No Power / Dead Boiler
Advertisements