E16
Dettson Outdoor Temperature Sensor Fault

Boiler shows E16 and indicates outdoor sensor error on the display

Advertisements

Possible Causes

Open or shorted Dettson outdoor sensor, Damaged exterior cable, Incorrect sensor type installed, Control board input failure

How to Fix / Troubleshooting

Safety: Turn off power before working on wiring.

  • Locate outdoor sensor: The Dettson outdoor sensor is typically mounted on an exterior north or northwest wall, away from direct sun.
  • Inspect cable: Follow the sensor cable back to the boiler. Look for cuts, staples through the wire, or UV damage.
  • Check connections: Reseat the sensor wires at the boiler control terminals, ensuring correct polarity if required.
  • Sensor test: A technician can measure resistance at the sensor and compare to Dettson's temperature/resistance chart. Replace the sensor if out of range.
  • Control board: If a known-good sensor still triggers E16, the outdoor sensor input on the control board may be defective.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Dettson outdoor temperature sensor
Check Price on Amazon