E11
Dimplex
Plate Heat Exchanger Flow Restriction / Overheat
Boiler shows E11; intermittent hot water; burner cycles rapidly on and off
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled or blocked Dimplex plate heat exchanger, Insufficient primary flow due to partially blocked Dimplex system filter, Faulty Dimplex modulating gas valve causing overheating at low flow
How to Fix / Troubleshooting
Safety first: Allow the boiler to cool before touching any pipework. Limescale removal chemicals must be handled by trained personnel.
User checks:
- System pressure and radiator valves: Ensure pressure is correct and all radiator valves are open to allow adequate circulation.
- Clean external filters: If a user-serviceable magnetic filter is installed on the return to the Dimplex boiler, follow the manufacturer’s instructions to clean it.
Professional repair:
- Isolate and chemically flush or replace the Dimplex plate heat exchanger.
- Check primary circulation and clean internal Dimplex filters or strainers.
- Verify correct modulation of the Dimplex gas valve and adjust via the PCB if required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Dimplex plate heat exchanger
Check Price on Amazon