E01
Boiler will not start; lockout light on; E01 displayed on Dimplex control panel
Ignition Failure / Flame Not Detected
E02
Boiler shuts down shortly after starting; E02 displayed; overheat or high temperature lockout
Primary Heat Exchanger Overheat / High Limit Trip
E03
Boiler attempts to start but shuts down with E03; fan runs briefly or not at all; possible flue or air pressure fault
Flue Fan / Air Pressure Switch Fault
E04
Boiler displays E04 and will not fire; low system pressure warning or water shortage
Low Water Pressure / Water Shortage Protection
E05
Boiler shows E05; no heating or hot water; temperature reading on display is unrealistic or fixed
Flow Temperature Sensor (NTC) Fault
E06
Boiler displays E06; domestic hot water temperature unstable or not recognised
DHW Temperature Sensor (NTC) Fault
E07
Boiler shows E07; fan runs but burner does not light; sometimes accompanied by flue-related warning icon
Flue Gas Temperature Sensor / Overheat Fault
E08
Boiler displays E08; pump symbol may flash; no circulation to radiators or cylinder
Circulation Pump Fault
E09
Boiler shows E09; no response to thermostat demand; control panel may be blank or partially lit
Main Control PCB Fault
E10
Boiler displays E10; domestic hot water runs cold; burner does not fire on hot water demand
Flow Switch / Flow Sensor Fault (DHW Demand Not Detected)
E11
Boiler shows E11; intermittent hot water; burner cycles rapidly on and off
Plate Heat Exchanger Flow Restriction / Overheat
E12
Boiler displays E12; no heating; room thermostat appears to call for heat but boiler does not respond
Communication Fault Between Boiler PCB and Room Controller
E13
Boiler shows E13; frequent lockouts during cold weather; condensate pipe may gurgle
Condensate Drain Blocked / Frozen
E14
Boiler displays E14; burner shuts down unexpectedly; gas valve symbol may flash
Gas Valve Modulation / Control Fault
E15
Boiler shows E15; fan symbol may be present; burner does not ignite
Fan Speed / Tachometer Feedback Fault
E16
Boiler displays E16; safety lockout; may be accompanied by high temperature reading
Safety Thermostat / Overheat Cut-out Tripped
E17
Boiler shows E17; display may indicate sensor mismatch; boiler may run at reduced output
Flow/Return Temperature Differential Fault
E18
Boiler displays E18; no heating; external controls appear normal
External Safety Interlock Open (e.g., Overheat, Low Water Cut-off)
E19
Boiler shows E19; display may flicker; intermittent operation
Supply Voltage / Power Quality Fault
E20
Boiler displays E20; no heating; cylinder icon may flash on system/heat-only models
Cylinder Sensor / Cylinder Thermostat Fault
Symptom
Boiler casing or flue area shows signs of soot or black staining
Incomplete Combustion / Flue Gas Spillage
Symptom
Boiler cycles on and off rapidly, causing fluctuating radiator and hot water temperatures
Short Cycling / Oversized Boiler or Control Issue
Symptom
Boiler display is blank but fused spur is on
No Power to Control Electronics
Symptom
Boiler does not fire for hot water unless heating is also on (on system/heat-only setups)
Motorised Valve / Hot Water Control Fault
Symptom
Boiler does not fire in very cold weather; external condensate pipe is exposed
Frozen Condensate (Weather-Related Lockout)
Symptom
Boiler does not respond to room thermostat; heating stays off even though hot water works
External Control / Thermostat Circuit Fault
Symptom
Boiler emits a burning smell or plastic smell during operation
Overheating Electrical Component or Insulation
Symptom
Boiler frequently locks out and requires manual reset, with no consistent error code
Intermittent Control or Sensor Fault
Symptom
Boiler frequently loses pressure and needs topping up every few days
Chronic Pressure Loss
Symptom
Boiler is very noisy with whirring or grinding sounds from inside the casing
Mechanical Wear of Fan or Pump
Symptom
Boiler leaking water from underneath the casing
Internal Water Leak
Symptom
Boiler makes loud banging or knocking noises (kettling) during operation
Heat Exchanger Kettling / Localised Boiling
Symptom
Boiler runs but hot water temperature at taps is inconsistent or too hot/cold
Domestic Hot Water Temperature Control Issue
Symptom
Boiler runs but radiators do not get hot or only partially warm
Poor Heating Circulation
Symptom
Boiler starts then shuts down after a few seconds without showing a specific error code
Flame Detection Instability
Symptom
Boiler vibrates excessively or rattles when running
Mechanical Vibration / Mounting Issue