E17
Dimplex Flow/Return Temperature Differential Fault

Boiler shows E17; display may indicate sensor mismatch; boiler may run at reduced output

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty Dimplex return NTC sensor, Poor circulation due to partially closed valves or undersized pipework, Blocked Dimplex system filter or heat exchanger, Incorrect pump speed setting

How to Fix / Troubleshooting

Safety first: Turn off power before accessing sensors or pump controls.

User checks:

  • Radiator valves: Ensure all radiator and isolation valves are open.
  • System filter: If a user-serviceable filter is installed, clean it according to instructions.
  • Reset: After improving circulation, reset the boiler and monitor performance.

Professional repair:

  • Test Dimplex flow and return NTC sensors and replace any faulty units.
  • Balance the heating system and adjust Dimplex pump speed.
  • Clean or replace blocked Dimplex heat exchangers.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Dimplex return NTC temperature sensor
Check Price on Amazon

We may earn a commission from links on this page.