E15
Dimplex
Fan Speed / Tachometer Feedback Fault
Boiler shows E15; fan symbol may be present; burner does not ignite
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed tachometer sensor in Dimplex fan assembly, Obstructed fan impeller, Loose fan connector to Dimplex PCB, Faulty Dimplex PCB fan driver circuit
How to Fix / Troubleshooting
Safety first: Isolate power before accessing the fan compartment. Do not run the boiler with covers removed.
User checks:
- Flue terminal: Ensure the external Dimplex flue terminal is clear to avoid overloading the fan.
- Reset: After confirming the flue is clear, reset the boiler and see if E15 clears.
Professional repair:
- Inspect and clean the Dimplex fan impeller and housing.
- Test tachometer feedback to the Dimplex PCB and replace the fan assembly if defective.
- Check PCB fan driver output and replace the Dimplex PCB if required.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Dimplex flue fan assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements